C200H AC Servo Manual
41
Digital Output(DO)
Parameter
Introduction
Range
Default Value
PA16
Range of positioning completion
0-3000 pulses
130
PA17
Position deviation limit
0-30000×100 pulses
6000
PA18
Position deviation error
0-1
0
PA83
CWL,CCWL prohibited mode
0-1
0
PA84
Hysteresis for position completion
0-32767
65
PA85
Range for approach positioning
0-32767
6500
PA86
Hysteresis for approach positioning
0-32767
650
Input And Output Terminals
Parameter
Introduction
Range
Default Value
PA55
Effective level control word for input
terminals
0000-1111
0000
PA57
Effective level control word for output
0000-1111
0000
PA58
Time constant of removing jitter for IO
input terminal
1-20ms
2
P3-0
Digital Input DI1 function
0-99
1
P3-1
Digital Input DI2 function
0-99
2
P3-2
Digital Input DI3 function
0-99
3
P3-3
Digital Input DI4 function
0-99
4
P3-4
Digital Input DI5 function
0-99
5
P3-5
Digital Input DI6 function
0-99
6
P3-6
Digital Input DI7 function
0-99
7
P3-7
Digital Input DI8 function
0-99
8
P3-15
Force digital input valid1
00000000-11111111
00000000
P3-16
Force digital input valid2
00000000-11111111
00000000
P3-17
Force digital input valid3
00000000-11111111
00000000
Содержание C200H Series
Страница 1: ...https en coolmay com ...
Страница 2: ...C200H AC Servo Manual https en coolmay com ...
Страница 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Страница 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Страница 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...
Страница 64: ...C200H AC Servo Manual 57 No 4 alarm ...
Страница 119: ...C200H AC Servo Manual 112 Version 22 51 ...