C200H AC Servo Manual
90
7.2.4 DI
Forced Valid
There are 5 parameters( P3-15, P3-16, P3-17,P3-18,P3-19) in group P3 and they can force
DI valid.
(1)
Corresponding functions for P3-15 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function
CZERO
ZCLAMP
TCW
TCCW
CWL CCWL ARST
SON
(2)
Corresponding functions for P3-16 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function
CMODE
NULL
TRQ2
TRQ1
NULL
SP2
SP1
CINV
(3)
Corresponding functions for P3-17 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function
NULL
JOGN
JOGP
INH
CLR
GEAR2
GEAR1
NULL
(4)
Corresponding functions for P3-18 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function NULL POS2
POS1
POS0
CTRG
HOLD
NULL
NULL
(5)
Corresponding functions for P3-19 is represented by 8-bit binary:
Number
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Function NULL NULL
NULL
NULL
NULL
NULL
ORGP
SHOM
Parameter Meaning:
One of 5 parameters
Corresponding Function
Result
0
Unplanned
OFF
(
invalid
)
Already Planned
It is up to signals
1
Unplanned Or Already Planned
ON
(
forced valid
)
Being planned means that the parameter has been selected by the input
terminal in the P3-0~P3-3.
Содержание C200H Series
Страница 1: ...https en coolmay com ...
Страница 2: ...C200H AC Servo Manual https en coolmay com ...
Страница 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Страница 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Страница 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...
Страница 64: ...C200H AC Servo Manual 57 No 4 alarm ...
Страница 119: ...C200H AC Servo Manual 112 Version 22 51 ...