C200H AC Servo Manual
19
Input Circuit Of Pulse Instruction Diagram
1
)
When it is differential mode:
2
)
When it is collector open mode:
A
)
For internal 24V power sources:
Common Anode Connection, for example: Mitsubishi PLC.
If the output pulse width of the upper device is less than the minimum pulse
width, it will cause the drive to receive error pulses.
The terminal between PULS+ and PULS-/SIGN+ and SIGN- only support
below 5V signal. If over than 5V, it needs to connect external resistances.