C200H AC Servo Manual
29
Shielded Ground
Metal Cover
Connect with the shielded layer of the ecoder
cable
4.5.3
CN2B Terminal Introduction
The encoder signal connector CN2B connects with the absolute encoder. A 6 pins plug is
used. The pin chart as followings:
Pic 4.8 CN2B Encoder Signal Terminal
4.5.2
CN2B Terminal Signal Introduction
Signal Name
Pin No.
Function
Encoder Power Supply
5V
5
Use 5V power supply (Provided by servo
driver). If the cable is longer than 20m and
prevent encoder from voltage dropping down,
multi wires or thick wires is recommended
for power cable and ground cable.
0V
6
Absolute encoder
communication positive
SD+
1
Absolute encoder communication positive end
Absolute encoder
communication negative
SD-
2
Absolute encoder communication negative end
Null terminal
NC
3
Retain
Null terminal
NC
4
Retain
Shielded layer
Metal cover
Connect to the shielded layer of the encoder cable