C200H AC Servo Manual
50
5.4 Origin Regression Function And Relevant Parameters Introduction
5.4.1 Relevant Parameter Settings
Parameter
Introduction
Value
Default Value
P4-32
Origin detector type or search direction
setting
0-5
0
P4-33
Set the model of short distance movement
to the origin
0-2
0
P4-34
Origin trigger start mode
0-2
0
P4-35
Origin stop mode setting
0-1
0
P4-36
The first stage of high speed origin
regression speed setting
1-2000 r/min
1000
P4-37
The second stage of low speed origin
regression speed setting
1-500 r/min
50
P4-38
Cycles of origin regression offset
+/-30000
0
P4-39
Pulses of origin regression offset
+/-max cnt
0