4.7 Anti-jamming Countermeasures of Power Wiring
To suppress interference, please take the following measures:
Instruction input cable length should be less than 3 meters,and encoder cable should be less
than 20 meters.
Recommend grounding cable over 2.0 mm²
Please install a noise filter on the input side of the power cable to prevent radio frequency
interference.
To avoid electromagnetic interfering, the following methods can be used:
1
)
Install the upper device and a noise filter near the servo drive.
2
)
Install a surge suppressors on coils of relays, solenoids, electromagnetic contacts.
3
)
Separate high and low voltage cables away minimum at 30 cm.
4
)
Do not share a power supply with welding devices, discharge processing devices, etc. When
there is a high frequency generator nearby, please install a noise filter on the input side of the
power cable.
4.7.1 Wiring Examples Of Anti-Jamming And Ground Handling
1. Examples of anti-jamming wiring
Pic 4.13 A Example Of Anti-Jamming Wiring