Follow Run Dry
Follow Isolate
Aux Timer
Time that the PGM will change state.
Settings 0 to 120 minutes in 1 second
intervals.
Follow Zone
Used to set the required Zone (1 to 6)
if «Follow Zone» selected. Displays as
"Zone number (current)>(new
selection)".
Entry/exit time
00 min 00 sec 0 to 3 minutes in 1
second intervals
Time that the Smoke Screen will
ignore activation demands after the
Zone 1 (Alarm Set ) input is made
active.
Energy Save
Mode
Off
Off
Extreme
On
Enables or disables the ESM. «On»
lowers the block temperature when
Zone 1 is “Unset” and with «Extreme»
set the block is not heated when Zone
1 is “Unset”. For more information see
the section on “Energy Saving Mode”.
Siren
Loudness
0
0 to 1
Sets the audio output volume.
Siren
Frequency
1000Hz
100 to 5000 Hz in 100
intervals between 100
and 1000 then 500
intervals to 5000
Sets the audio output frequency.
Temperature
PCB
35
o
C
10
o
C to 40
o
C in 1
o
C
intervals
Sets the PCB temperature at which the
onboard fan will operate.
Installer Code
1993
0000 to 9999
Set the installer access code by
selecting each digit and adjusting from
0-9.
Menu Timeout
30 min
1 to 99 minutes in 1
minute intervals
Set the time after the last key is
pressed that the User Menu will stay
open.
DHCP
On
On
Off
IP
192.168.010.10
Adjustable by digit
Item available if DHCP = “Off”. System
must be restarted using the menu
command to register a change.
27