5.5.2 RS485
When this is utilized, one Smoke Screen can be set as the master system which will then control up to 9
slaves on the same bus. It is possible to chain many more using a dedicated controller from Concept
Smoke Screen.
When making use of this feature, the following things become true:
1. The master SSM operates as a global input and output point for the controlling alarm system
(where used).
In this scenario, any attached slave system that develops a local fault, will trigger a global fault at
the master.
The slaves will follow the “Set” and “Trigger” status of the master and will then operate when they
detect movement on a locally attached hold off detector. If “hold-off chain” is selected on the
master, a slave that detects a hold off alarm, will pass the signal to all attached generators
(including the master) and the whole system will trigger.
Equally, if “Panic propagate” is selected at the master, a triggered panic input at the master or any
attached slave, will trigger the whole chain. When this is de-selected, each panic input will operate
only the SSM it is attached to.
2. The master generator is capable of providing full information over a serial connection relating to
the condition of itself and all of the attached slaves to TitanConfig. This can then be displayed as a
wall of information providing easy visual information of the entire system. See TitanConfig manuals
for more information on this feature.
3. It is not possible to have 2 masters on the same bus – each assignment must be unique.