Subnet Mask
255.255.255.0
00
Adjustable by digit
Item available if DHCP = “Off”. System
must be restarted using the menu
command to register a change.
Gateway
192.168.002.0
01
Adjustable by digit
Item available if DHCP = “Off”. System
must be restarted using the menu
command to register a change.
TFTP Update
IP
080.112.203.00
6
Adjustable by digit
System must be restarted using the
menu command to register a change.
SNMP IP
000.000.000.
000
Adjustable by digit
System must be restarted using the
menu command to register a change.
SNMP
Username
Default
Default
ConceptSSM
Allows a limited function set to
become available to a remote user (i.e.
security manager or remote fault
monitoring centre). Select
“ConceptSSM” to enable.
Update
Firmware
No
Yes
Contacts the TFTP Update Server, and
downloads and deploys a new
firmware set if one is available.
Restart
System
No
Yes
Restarts the system. This is needed to
change to the networking settings to
take effect.
Fluid
Replenish
No
Yes
Used if the use of an external reservoir
has been set by Concept Smoke
Screen (facility not available to the
installer). Select Esc for No and Enter
for Yes.
Reset Settings
Factory Default
Defaults the system to factory settings
(NB: These may be different to
delivery settings).
Tamper
Enable
Tamper Front
Enabled
Enabled
Disabled
Tamper function enable or disable.
Tamper Fluid
Tamper
Battery
Tamper Back
Tamper
External
Disable Fan
Fan enabled.
Fan enabled.
Fan disabled.
Switch the fan function on or off.