(Z6) Isolate
Normally
closed
Not used
Normally Open
Normally closed
Double EOL
Single EOL
(EOL values available =
1k, 2k2, 2k7, 3K,
3K3,4K7, 5k6, 6k2)
Defines the type of input the Smoke
Screen requires to be isolated through
Zone 6.
Ready output
Normal (NC)
Normal (NC)
Inverted (NO)
Defines the output state when the
Smokescreen is ready to activate.
Tamper output
Normal (NC)
Normal (NC)
Inverted (NO)
Defines the output state when the
Smokescreen is not in tamper alarm.
Battery output
Normal (NC)
Normal (NC)
Inverted (NO)
Defines the output state when the
Smokescreen battery power is ok.
Mains F.
output
Normal (NC)
Normal (NC)
Inverted (NO)
Defines the output state when the
Smokescreen mains power is ok.
Fluid L. output
Normal (NC)
Normal (NC)
Inverted (NO)
Defines the output state when the
Smokescreen fluid is above 50%.
Fluid E. output
Normal (NC)
Normal (NC)
Inverted (NO)
Defines the output state when the
Smokescreen fluid is above empty.
Smoke output
Normal (NC)
Normal (NC)
Inverted (NO)
Defines the output state when the
Smokescreen is making smoke.
PGM 1/2/3
output*
Normal (NO)
Normal (NC)
Inverted (NO)
Sets the state of the PGM Outputs.
Settings available are “Normally
closed” and “Normally open”.
PGM 1/2/3
function*
Disabled
Disabled
Function not in use.
Follow Pump Fuse F
PGM follows selected function.
Follow Nozzle F
Fire Panel Isolate
Follow Fluid Med
Follow Overheat
Follow Underheat
Follow Thermal Fault
Iris Mode
Not used
Follow Trouble/Tmp
PGM follows selected function.
26