INSTALLER TIME & DATE MENU
MENU ITEM
SUB-MENU ITEM
DELIVERY SETTING DESCRIPTION
Set Time
12:00
Set current time in hours and minutes.
Set Date
00:00:0000
Set current date in dd:mm:yyyy.
Set Time Zone
0
0=GMT. Each addi1 or -1 is the
respective amount away from GMT.
INSTALLER CONFIGURATION MENU
MENU ITEM
SUB-MENU
ITEM
DELIVERY
SETTING
Available settings
DESCRIPTION
SSM Mode
EN-50131-8
EN-50131-8
IRIS
Determines whether the Smoke
Screen will operating mode.
Isolate unit
On
On
Off
Isolate Mode that stops any activation
and makes the «Ready» output «Not
Ready». The LCD flashes when
selected «On».
Z6 Function
Isolate
Disabled
Isolate
Function not in use.
Zone 6 can be used by an external
source to prevent the Smoke Screen
activating.
Mbus Mode
Slave (CCS)
Master
Slave (CCS)
Slave 1 to 9
RS485 configuration. When configured
as Master, options become available
to propagate SNMP (remote) triggers
to the chain, propagate panic inputs
from any point to the whole chain and
propagate hold off inputs from any
point to the whole chain. Refer to the
"Enhanced Communications and
Integration" section for further
information.
23