Settings
5
5.1 ISOLATE (SERVICING) MODE
To prevent the Smoke Screen from making smoke whilst work is conducted with power applied it can be
put into a servicing mode by selecting the “Isolate” function at the start of the Installer Configuration Menu
to ‘on’.
FAILURE TO DISABLE ISOLATE WHEN NO LONGER REQUIRED WILL PREVENT THE SMOKE SCREEN
OPERATING.
5.2 TAMPER
There are 4 internal tamper circuits on the Smoke Screen, one on each cover (front, battery and fluid) and
one through the rear of the case for a bracket tamper. There is also an external tamper input on the PCB
for the monitoring of peripheral devices. On a tamper alarm the Smoke Screen provides an output
indication of the event and automatically activates if the Zone 1 (Set) is in alarm. If the Smoke Screen is not
mounted on its bracket the bracket tamper should be by-passed to prevent unwanted tamper warnings.
The LCD display and control buttons are disabled if the front tamper is closed.