Smoke Delay
00 min 00 sec 0 to 2 minutes in 1
second intervals.
Sets the time the Smoke Screen will
wait after an activation demand before
producing smoke.
(Z1) Set Input
Normally
closed
Not used
Normally Open
Normally closed
Double EOL
Single EOL
(EOL values available =
1k, 2k2, 2k7, 3K,
3K3,4K7, 5k6, 6k2)
Defines the type of input the Smoke
Screen requires to sense an Alarm Set
state. Stops all activations except
panic.
(Z2) Trigger
Inp
Normally
closed
Not used
Normally Open
Normally closed
Double EOL
Single EOL
(EOL values available =
1k, 2k2, 2k7, 3K,
3K3,4K7, 5k6, 6k2)
Defines the type of input the Smoke
Screen requires to sense a Trigger
alarm.
(Z3) Top-up
Detec
Normally
closed
Not used
Normally Open
Normally closed
Double EOL
Single EOL
(EOL values available =
1k, 2k2, 2k7, 3K,
3K3,4K7, 5k6, 6k2)
Defines the type of input the Smoke
Screen requires to sense an alarm
state for the Top-up detector (Screen
Sensor). Settings available are
“Normally closed”, “Normally open”, a
range of EOL resistance settings or
“Not used”.
(Z4) Hold-Off
Inp
Normally
closed
Not used
Normally Open
Normally closed
Double EOL
Single EOL
(EOL values available =
1k, 2k2, 2k7, 3K,
3K3,4K7, 5k6, 6k2)
Defines the type of input the Smoke
Screen requires to sense a hold off
alarm. Settings available are “Normally
closed”, “Normally open”, a range of
EOL resistance settings or “Not used”.
(Z5) Panic Trig.
Normally
closed
Not used
Normally Open
Normally closed
Double EOL
Single EOL
(EOL values available =
1k, 2k2, 2k7, 3K,
3K3,4K7, 5k6, 6k2)
Defines the type of input the Smoke
Screen requires to sense a panic
alarm state. A panic input ignores the
condition of all other inputs and will
trigger the generator for the set “Panic
smoke” time.
25
Содержание TITANIUM Ti100