Top up life
cycle
30 minutes
1 to 120 minutes in 1
minute intervals
Limits top up operations by time.
When a Screen Sensor is used on Z3,
this setting will cause the SSM to
ignore further inputs from the Screen
sensor after the timer has expired. The
timer begins after the first cycle of fog
production i.e. if the “Smoke on” time
is set to 2 minutes, the top up life
cycle commences after 2 minutes.
Top up % time
25%
0 to 100% in 1%
intervals
Sets top up operation as a % of
“Smoke on time”. If the Screen sensor
detects a drop-in fog density, the SSM
will operate according to how this is
set.
Smoke on
time
01min 00 sec
0 to 15 minutes in 1
second intervals
Sets duration of first burst. Timer only
runs when fog is being actively
produced. Rest phases are ignored.
Pump 2
smoke time
01min 00 sec
0 to 1 minute in 1
second intervals
Ti150D function only. Sets duration of
second pump run time on an
activation demand.
Panic smoke
time
01min 00 sec
0 to 15 minutes in 1
second intervals
Sets duration of Panic smoke time.
Timer only runs when fog is being
actively produced. Rest phases are
ignored.
Smoke Pulse
Pulse on time
00min 00 sec
0 to 15 minutes in 1
second intervals
THESE SETTINGS SHOULD NOT BE
CHANGED
Pulse high
time
1
1 to 60 in intervals of 1.
Pulse low time 1
1 to 60 in intervals of 1.
Low incr. time
0
0 to 60 in intervals of 1.
Hold off
On
On
Off
Enables hold-off retriggering. When
“Smoke on” timer expires, and an
intruder condition still exists, if the
hold-off reactivates, the SSM will
re-trigger according to the sub-menu
settings.
Hold off time
25%
0 to 100% in 1%
intervals
Item available if Hold off set to “On”.
Sets the re-triggering activation time
as a % of the set “Smoke on” time.
Hold off rep nr 10
0 to 50 in single
intervals
Item available if Hold off set to “On”.
Sets the number of times the SSM will
retrigger when hold-off reactivates.