background image

 

 www.vega-absolute.ru 

 

 

 

 

 

MOTION SENSOR 

SMART-MS0101 

 

User Manual 

 

 

 

 

 

 

 

Infrared motion sensor Vega Smart-MS0101 is designed 
to detect penetration into the protected area. The 
sensor alternately operates in two modes: «Guard» and 
«Neutral». Sends an alarm signal to the LoRaWAN™ 
network by the triggering. 

 

 

Содержание Smart-MS0101

Страница 1: ...MS0101 User Manual Infrared motion sensor Vega Smart MS0101 is designed to detect penetration into the protected area The sensor alternately operates in two modes Guard and Neutral Sends an alarm signal to the LoRaWAN network by the triggering ...

Страница 2: ...V05 MS0101 01 Revision and date 03 28 09 2018 This document applies to the following products Product name Type number Vega Smart Vega Smart MS0101 Revision History Revision Date Name Comments 01 08 12 2017 KEV Document creation date 02 08 08 2018 KEV Technical characteristics are added new part is added 03 28 09 2018 KEV Typo at the communication protocol was fixed ...

Страница 3: ...mounting recommendations 10 Connecting via USB 11 4 VEGA LORAWAN CONFIGURATOR 13 Interface of the application 13 Connection to the device 14 Device info tab 15 LoRaWAN settings tab 16 Smart MS0101 tab 21 5 COMMUNICATION PROTOCOL 22 SMART MS0101 transmits the following types of packets 22 6 STORAGE AND TRANSPORTATION REQUIREMENTS 23 7 CONTENT OF THE PACKAGE 24 8 WARRANTY 25 ...

Страница 4: ... Vega Absolute LLC and provides information on powering and activation procedure control commands and functions of the device This manual is targeted at specialists familiar with installation work fundamentals for electronic and electrical equipment The device shall be installed and adjusted by qualified specialists in order to ensure proper operation of the device ...

Страница 5: ... is detected If the movement in the protected area has ceased then the device switches back to the Guard mode after a certain configurable period of time Auto post time interval is setting up by the Vega LoRaWAN configurator application and may vary from 1 to 60 minutes Vega Smart MS0101 can be used to protect premises buildings and structures as well as in Smart Home systems built on LoRaWAN tech...

Страница 6: ...6 12 or 24 hours Antenna internal Sensitivity 138 dBm Radio coverage in restrained urban conditions max 5 km Radio coverage within line of sight max 15 km Power output up to 100 mW configurable Power Replaceable battery CR123A 3V 1400 mAh Case Housing dimensions 35 х 50 х 70 mm Ingress protection rating IP41 Vega Smart MS0101 motion sensor is class A device LoRaWAN classification and has the follo...

Страница 7: ...ted area but no more than one at 10 seconds One more indicator is located on the board and it shown only when cover off and displays a linking to the network state Indicator signal Meaning A series of short red flashes Linking to the network One long red flash The device switched to the Storage mode Indicator on the front of the device case Indicator on the device case Indicator on the board ...

Страница 8: ...ving the polarity before start The sensor supports two activation methods in the LoRaWAN network ABP and OTAA Select one of the methods using Vega LoRaWAN Configurator application See part 4 1 ABP After pressing the start button the device immediately starts working in the Active mode Вставить батарейку CR123А в батарейный отсек Нажать кнопку запуска расположенную на плате ...

Страница 9: ...signal and switches to the Active mode If all attempts fail the sensor switches to the Storage mode To manually switch the device from the Active mode to the Storage mode you can use the long press of the start button more than 5 seconds Before connecting the device make sure that its registration data is entered in the network Device EUI Application EUI and Application Key for OTAA or Device addr...

Страница 10: ...near objects that are powerful sources of heat or have the ability to quickly change their temperature fireplaces stoves air conditioners radiators etc in places with strong air currents or the possibility of direct sunlight The wall on which the sensor is mounted should not be subjected to strong vibrations The presence in the detection zone of objects curtains screens large objects furniture pla...

Страница 11: ...h the Vega LoRaWAN Configurator application See part 4 Before connecting the device to the computer for the first time you must install the driver for the COM port stsw stm32102 which can be downloaded from iotvega com After running the executable file VCP_V1 4 0_Setup exe the installer window will appear micro USB ...

Страница 12: ...s window you need to click Next then Install and then the installation will begin When the installation is completed successfully the following screen appears After pressing Finish the driver is ready for operation it is possible to connect the device via USB ...

Страница 13: ...nal from the gateways are available Next the work of the configurator is considered in the Expert mode INTERFACE OF THE APPLICATION The Vega LoRaWAN Configurator application does not require the special installation When the executable file is launched the window for working with the application appears See Fig 4 1 Fig 4 1 The Vega LoRaWAN Configurator application interface The menu on the left al...

Страница 14: ...n in the menu on the left The configurator automatically recognizes the type of device and the device selection menu becomes inactive Fig 4 2 Connection to the device To read the settings from the device you need to click the Get settings button until this point the application will display the default settings or from the last connected device After making the necessary changes to the settings yo...

Страница 15: ...vice in the LoRaWAN network with OTAA method Over The Air Activation is displayed Regional info not displayed in the Simple mode shows the frequencies of the JOIN channels and the second receiving window These frequencies can be changed in the LoRaWAN Settings tab when selecting a frequency plan Device info the configurator reads information about the device model its firmware and automatically co...

Страница 16: ...l occurs Link check not displayed in the Simple mode when pressed the device sends a special signal to the LoRaWAN network in response to which the network informs it of the number of gateways that received this signal and the signal quality This button only works when the device is connected to the network Device output not displayed in the Simple mode monitoring the device status all events in r...

Страница 17: ... 125 kHz Custom Set with Vega LoRaWAN Configurator application In the EU_868 and RU_868 frequency bands only 3 channels are active by default The device sends requests for connection to the network on this join channels The remaining channels that the device should use can be transferred by the LoRaWAN network server during the device activation procedure only OTAA If you select Custom in the Regi...

Страница 18: ...ill retry sending the packet until it receives the server confirmation or until the Uplink number of transmission is over see below ADR this option activates the Adaptive Data Rate algorithm for automatic control of the data transfer rate from the LoRaWAN network side The higher the quality of the signal received by the network the higher the speed will be installed on the device This option is re...

Страница 19: ... LoRaWAN network The second window always opens after 1 second after the first Uplink number of transmission not displayed in the Simple mode if the Confirmed uplinks function is disabled the device will simply send each packet as many times as specified in this option If Confirmed uplinks is enabled the device will send packets until it receives a confirmation or until it sends as many packets as...

Страница 20: ...adjusted to this value when sending packets to the LoRaWAN network This option can be changed by the network server TX datarate not displayed in the Simple mode the device transmission datarate at which it will transfer packets to the LoRaWAN network This speed can be changed by the network server if the ADR algorithm is enabled ...

Страница 21: ... MS0101 tab Current state displays the current parameters of the device the internal temperature of the device and the battery level Guard settings allows setting the time interval of auto post to the Guard mode from 1 to 60 minutes Data transmission settings the transmission period which the packet with the current readings is transmit See part 5 packet 1 ...

Страница 22: ...ery time alarm event occurs Size in bytes Field description Data type 1 byte Packet type 1 for that packet uint8 1 byte Battery charge uint8 1 byte Values of basic settings byte field uint8 2 bytes Temperature in С multiplied by 10 int16_t 1 byte Sending reason 0 by the time 1 alarm uint8 1 byte reserve uint8 Values of basic settings bit field decoding Bits Field description 0 bit Activation type ...

Страница 23: ...N REQUIREMENTS The Smart MS0101 sensor shall be stored in the original packaging in heated room at temperatures 5 С to 40 С and relative humidity less than 85 The sensor shall be transported in covered freight compartments of all types at any distance at temperatures 40 C to 85 C ...

Страница 24: ...Smart MS0101 User Manual 24 Revision 03 28 09 2018 7 CONTENT OF THE PACKAGE The sensor is delivered complete with Motion sensor Vega Smart MS0101 1 pc CR123A battery 1 pc Factory certificate 1 pc ...

Страница 25: ...ge and operation specified in this user manual Warranty does not apply to power supply elements the device with mechanical electrical and or other damages and defects caused by violation of the transportation storage and operation requirements the device with traces of repair performed not by the manufacturer s service center the device with traces of oxidation or other signs of liquids leaking in...

Страница 26: ...Smart MS0101 User Manual 26 Revision 03 28 09 2018 vega absolute ru Operation Manual Vega Absolute LLC 2017 ...

Отзывы: