Miscellaneous
8
8.1 FAQ
Q
The Smoke Screen is indicating it is ready to operate, but does not respond to a full alarm
test.
A
Ensure the smoke machine is not isolated.
With power applied, and keeping clear of the smoke nozzle, disconnect the “Alarm”/”Trigger”
and “Hold Off” connection plugs from the PCB. If the Smoke Screen produces smoke there is
a mis-connection in the system wiring.
Q
The Smoke Screen is puffing out smoke whilst heating up.
A
This is the result of very small amounts of air and residual fluid in the heater block being
changed into an insignificant volume of smoke and can happen particularly after the Smoke
Screen has been moved about when cold.
36
Содержание TITANIUM Ti100
Страница 1: ...TITANIUM Ti70 Ti100 Ti150 INSTALLATION AND OPERATION MANUAL VERSION 28 November 2019 ...
Страница 15: ...Titanium Generic Connection Schematic PCB v2 15 ...
Страница 37: ...8 2 INSTALLER NOTES 37 ...
Страница 39: ...39 ...