LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial Interface Operation (PS 1, PS 1.5 ONLY)
Revision 3
5–15
Parameter Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of Arguments)
Command
Query
Response to
Command
Response to
Query
Management IP
Address
IPA=
IPA?
18 bytes
Command or Query.
Sets or returns the Management IP Address and network prefix for the ‘J6 | COM1’ 10/100 BaseT Ethernet
management port, in the form xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx = the IP Address
yy = the network prefix (8 to 30)
NOTE:
Default Value = 192.168.001.004.24
COMMAND EXAMPLE:
<0001/IPA=192.168.001.004.24{CR}
CAUTION:
Changing the Management IP Address through the Telnet interface requires you to power cycle the
unit, and then restart a new Telnet session with the new IP Address. The IP Address that you type into the Telnet
client software does not include the range parameter so it would be: 192.168.1.4
IPA=
IPA?
IPA*
IPA#
IPA=xx.xxx.xxx.
xxx.yy
Gateway IP
Address
IPG=
IPG?
15 bytes
Command or Query.
Sets or returns the Gateway IP Address for the ‘J6 | COM1’ 10/100 Base Tx Ethernet management port, in the
form xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx = the IP Address
NOTE:
Default Value = 192.168.001.005
COMMAND EXAMPLE:
<0001/IPG=192.168.001.005{CR}
IPG=
IPG?
IPG*
IPG=xxx.xxx.xxx
.xxx
Initialize Statistics
Pointer
ISP=
N/A
None
Command only.
Resets the internal pointer to allow RNS? queries to start at the beginning of the stored statistics log. This
command takes no arguments.
EXAMPLE:
<0001/ISP={CR}
ISP=
ISP?
ISP*
N/A
Retrieve next 5
unread Stored
Alarms*
N/A
LNA?
145 bytes
Query only.
Returns the five oldest stored events in the alarm log, in the reply format:
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}{LF}
Where:
YYYYYYYYYY is the fault description.
ZZ is the event type FT = Fault; OK = Clear; or IF = Information
mmddyy hhmmss = date / time stamp.
NOTE:
If there are no events in the log the unit will reply with LNA*. All events that are read from the log are also
automatically removed from the log.
EXAMPLE:
<0001/LNA?{CR}
>0001/LNA={CR}
LOG CLR IF 175503 052307{CR}
FAN #1 FT 175504 052307{CR}
OVR TMP FT 175504 052307{CR}
FAN #1 OK 175504 052307{CR}
IIC BUS FT 175504 052307{CR}{LF}
LNA=
LNA=YY..ss
Содержание LPOD-R PS .5
Страница 4: ...ER LPODR EA3 Rev 2 Blank Page...
Страница 20: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Preface Revision 3 xviii Notes...
Страница 140: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 4 Figure B 4 Remove the Cover Plate...
Страница 151: ......
Страница 152: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...