LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial Interface Operation (PS 1, PS 1.5 ONLY)
Revision 3
5–24
Parameter Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of Arguments)
Command
Query
Response to
Command
Response to
Query
SNMP Trap
Destination IP
Address 2
STB=
STB?
15 bytes,
Numerical
Command or Query.
Sets or returns the IP Address of the SNMP Trap Destination IP Address 2 in the form xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx = IP Address
COMMAND EXAMPLE:
<0001/STB=010.006.030.002{CR}
NOTE:
When not configured, the Target returns >0001/STB=0.0.0.0{CR}{LF}
STB =
STB!
STB=xxx.xxx.xxx
.xxx
SNMP Trap
Version
STV=
STV?
1 byte
Command or Query.
Sets or returns the SNMP Trap Version that will be used to send traps in the form x, where:
1 = SNMP Trap Version 1
2=SNMP Trap Version 2
COMMAND EXAMPLE:
<0001/STV=0{CR}
STV =
STV!
STV=x
SNMP Write
Community
SWC=
SWC?
16bytes,
characters, no
spaces
Command or Query.
Sets or returns the SNMP Write Community string.
COMMAND EXAMPLE:
<0001/SWC=private{CR}
NOTE:
An empty string is not allowed.
SWC =
SWC!
SWC=x
Software Revision N/A
SWR?
34-37 bytes
Query only.
Returns the value of the internal software revision installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
-or-
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
SWR=
SWR=Boot:x.y.z
z Bulk1:x.y.zz
Bulk2:x.y.z
Set RTC Time
TIM=
TIM?
6 bytes
Command or Query.
Sets or returns the Real-Time-Clock time in the form hhmmss, where:
hh = hours, from 00 to 23;
mm = minutes, from 00 to 59,
ss = seconds, from 00 to 59
COMMAND EXAMPLE (time = 23 hours, 12 minutes and 59 seconds since midnight – i.e., 11:12:59 PM):
<0001/TIM=231259{CR}
TIM =
TIM?
TIM *
TIM=xxxxxx
Heatsink
Temperature
N/A
TMP?
5 bytes
Query only.
Returns the temperature of the Heatsink in the form sxxxx, where:
s = sign byte, positive or negative (+ or –)
xxxx = temperature (including decimal point)
EXAMPLE:
<0001/TMP?{CR}
<0001/TMP=+26.0{CR}{LF}
TMP=
TMP=sxxxx
Retrieve Number
of unread stored
Alarms*
N/A
TNA?
2 bytes
Query only.
Returns the number of stored events that remain unread in the alarm log in the form xx, where:
xx = number from 00 to 99.
NOTE:
Although a maximum of 255 events may be stored in the alarm log, event tallies greater than 99 are
reported as 99.
EXAMPLE:
<0001/TNA?{CR}
>0001/TNA=14{CR}{LF}
TNA=
TNA=xx
Содержание LPOD-R PS .5
Страница 4: ...ER LPODR EA3 Rev 2 Blank Page...
Страница 20: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Preface Revision 3 xviii Notes...
Страница 140: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 4 Figure B 4 Remove the Cover Plate...
Страница 151: ......
Страница 152: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...