LPOD-R Outdoor Amplifier / Block Up Converter
MN-LPODR
Ethernet Interface Operation
Revision 3
4–4
For correct SNMP operation, the LPOD-R MIB files must be used with the
associated version of the LPOD-R M&C. See the LPOD-R FW Release
Notes for information on the required FW/SW compatibility.
4.3
Telnet Interface
Chapter 5. OPTIONAL SERIAL INTERFACE OPERATION (PS 1, PS
1.5 ONLY)
The LPOD-R has a Telnet interface for the purpose of equipment M&C via the
optional Serial Remote Control protocol. The Telnet interface requires user login
at the
Administrator
level and
Read/Write
level. Once logged into the Telnet
interface as the Administrator, you have access to the optional serial-based
Remote Control Interface. An example of the login process and remote control
operation is shown here:
Figure 4-1. Telnet Interface Example – Windows Command-line
4.3.1
Using HyperTerminal for Telnet Remote Control Operation
There is a disadvantage when using Windows Command line as a Telnet client
with the optional Remote Control protocol. For the messages coming from the
Telnet Server, Command line cannot translate a carriage return command (
\r
) to
a carriage line feed command (
\r\n
). Therefore, any multi-line Target-
to-Controller response (e.g., the response to the FRW? query) shows as one line,
with the latter lines overwriting the previous lines.
Содержание LPOD-R PS .5
Страница 4: ...ER LPODR EA3 Rev 2 Blank Page...
Страница 20: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Preface Revision 3 xviii Notes...
Страница 140: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 4 Figure B 4 Remove the Cover Plate...
Страница 151: ......
Страница 152: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...