background image

LPOD-R Outdoor Amplifier / Block Up Converter (BUC) 

MN-LPODR / CD-LPODR 

Table of Contents 

Revision 3 

 

ix 

Table 2-3. LPOD-R PS .5 ‘J3 | POWER IN’ Pin Assignments ................................. 2–6 

Table 2-4. LPOD-R PS 1 ‘J3 | POWER IN’ Pin Assignments .................................. 2–7 

Table 2-5. LPOD-R PS 1.5 ‘J3 | POWER IN’ Pin Assignments ............................... 2–7 

Table 2-6. LPOD-R ‘J6 | COM1’ (OPTIONAL) Pin Assignments .......................... 2–11 

Table 2-7. LPOD-R PS .5 LED Operation ............................................................. 2–24 

FIGURES 

Figure 1-1. Comtech EF Data LPOD-R Outdoor Amplifiers / BUCs ...................... 1–1 

Figure 1-2. LPOD-R Typical Block Diagram .......................................................... 1–4 

Figure 1-3. LPOD-R PS .5 LED Indicator ............................................................... 1–6 

Figure 1-4. LPOD-R PS .5 C-Band 10W Unit ...................................................... 1–10 

Figure 1-5. LPOD-R PS .5 C-Band 20W Unit ...................................................... 1–11 

Figure 1-6. LPOD-R PS .5 Ku-Band 8W Unit ...................................................... 1–12 

Figure 1-7. LPOD-R PS .5 Ku-Band 16W Unit .................................................... 1–13 

Figure 1-8. LPOD-R PS 1 C-Band Unit – Coaxial Output .................................... 1–14 

Figure 1-9. LPOD-R PS 1 C-Band Unit ................................................................ 1–15 

Figure 1-10. LPOD-R PS 1 Ku-Band Unit ............................................................ 1–16 

Figure 1-11. LPOD-R PS 1.5 C-Band Unit ........................................................... 1–17 

Figure 1-12. LPOD-R PS 1.5 Ku-Band Unit ......................................................... 1–18 

Figure 2-1. LPOD-R PS .5 Connectors .................................................................. 2–3 

Figure 2-2. LPOD-R PS 1 Connectors ................................................................... 2–3 

Figure 2-3. LPOD-R PS 1.5 Connectors ................................................................ 2–3 

Figure 2-4. LPOD-R Ethernet Connector Field Termination Kit Assembly ........ 2–10 

Figure 2-5. Circular Connector Example ........................................................... 2–12 

Figure 2-6. LPOD-R Ground Connector Locations ............................................. 2–13 

Figure 2-7. PL/12319-1 Universal Pole Mounting Kit ........................................ 2–16 

Figure 2-8. Universal Pole Mounting Kit – Final Assembly ............................... 2–18 

Figure 2-9. KT-0000095 LPOD-R PS 1, PS 1.5 Single Unit Mounting Kit ............ 2–19 

Figure 2-10. SSPA Spar Mount Installation Example ......................................... 2–20 

Figure 2-11. LPOD-R PS 1, PS 1.5 Spar Mount Installation Kits ......................... 2–21 

Figure 2-12. KT-0020987 LPOD-R PS .5 OMT-Mount Installation Kit ................ 2–22 

Figure 2-13. LPOD-R PS .5 LED Indicator ........................................................... 2–23 

Figure 3-1. M&C Utilities Available from Comtech EF Data (All Current LPOD-R 

Models) ........................................................................................................ 3–3 

Figure 3-2. M&C Utilities Available from Comtech EF Data (Earlier LPOD-R PS1 or 

PS 1.5 Models) ............................................................................................. 3–4 

Figure 4-1. Telnet Interface Example – Windows Command-line ....................... 4–4 

Содержание LPOD-R PS .5

Страница 1: ...ubject to change without prior notice Part Number MN LPODR CD LPODR Revision 3 LPOD R Outdoor Amplifier Block Up Converter BUC LPOD R PS 5 Running FW 0020841 firmware only see MN LPODR Rev 0 for LPOD...

Страница 2: ...Copyright 2016 Comtech EF Data All rights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161...

Страница 3: ...upplies several voltages necessary for the unit to operate The 10V power supply output state is controlled by circuitry within the RF module If the RF module does not have the 5 8V supply for any reas...

Страница 4: ...ER LPODR EA3 Rev 2 Blank Page...

Страница 5: ...rences xii Examples of Multi Hazard Notices xiii Recommended Standard Designations xiii Safety and Compliance xiii Electrical Safety and Compliance xiii Installation Guidelines Regarding Power Line Qu...

Страница 6: ...cifications 1 7 1 5 1 Characteristics 1 7 1 5 2 Environmental 1 9 1 5 3 Physical 1 9 1 6 Dimensional Envelopes 1 10 1 6 1 LPOD R PS 5 Dimensional Envelopes 1 10 1 6 2 LPOD R PS 1 Dimensional Envelopes...

Страница 7: ...7 OMT Mount Installation PS 5 2 22 2 5 LPOD R Startup 2 23 2 5 1 Set the LPOD R Power ON 2 23 2 5 2 Monitoring LPOD R Operation with the LED Indicator PS 5 ONLY 2 23 2 5 3 Recovering the User Interfac...

Страница 8: ...eps to CReflash Upload the Firmware Files All LPOD R Models 3 13 3 4 3 Steps to FTP Upload the Firmware Files 3 14 3 4 4 Steps to Update the LPOD R Unit 3 15 CHAPTER 4 ETHERNET INTERFACE OPERATION 4 1...

Страница 9: ...15 4 5 3 1 Config Amplifier 4 15 4 5 3 2 Config Utility 4 16 4 5 4 Status Pages 4 18 4 5 4 1 Status Summary 4 18 4 5 4 2 Status Status 4 19 4 5 4 3 Status MOP 4 19 4 5 4 4 Status Events 4 20 4 5 4 5 S...

Страница 10: ...ommands and Queries 5 8 APPENDIX A CABLE DRAWINGS A 1 A 1 Overview A 1 A 2 Control and Data Cables A 1 A 2 1 Serial Interface Cable PS 1 or PS 1 5 OPTIONAL A 2 A 2 2 Ethernet Interface Cable PS 1 or P...

Страница 11: ...Figure 1 11 LPOD R PS 1 5 C Band Unit 1 17 Figure 1 12 LPOD R PS 1 5 Ku Band Unit 1 18 Figure 2 1 LPOD R PS 5 Connectors 2 3 Figure 2 2 LPOD R PS 1 Connectors 2 3 Figure 2 3 LPOD R PS 1 5 Connectors...

Страница 12: ...52 part of KT 0000203 A 3 Figure A 3 Ethernet Data Cable PP CAT5FF7FTGY A 4 Figure A 4 1 4 Heliax Coaxial Cable CA 3722 X A 6 Figure B 1 Comtech EF Data LPOD R Outdoor Amplifiers BUCs B 1 Figure B 2 L...

Страница 13: ...the LPOD R Related Documents Comtech EF Data CLC 10 Handheld Terminal M C Accessory for LPOD or SPOD User s Guide CEFD P N MN CLC10 Comtech EF Data LPODnet M C Netbook Accessory for LPOD or SPOD Oper...

Страница 14: ...References Patents and Trademarks See all of Comtech EF Data s Patents and Patents Pending at http patents comtechefdata com Comtech EF Data acknowledges that all trademarks are the property of the t...

Страница 15: ...Web Server Interfaces All other references in the manual refer to EIA designations CAUTION It is important that you review and understand the Safety and Compliance information that follows Safety and...

Страница 16: ...surge suppression at the power junction box Grounding The LPOD Rprovides a grounding terminal This is provided to allow you to ground the LPOD R to the antenna s grounding network All components insta...

Страница 17: ...s option repair or replace products that prove to be defective Repairs are warranted for the remainder of the original warranty or a 90 day extended warranty whichever is longer Contact Comtech EF Dat...

Страница 18: ...serial number of any of its parts has been altered defaced or removed The warranty does not cover damage or loss incurred in transportation of the product The warranty does not cover replacement or r...

Страница 19: ...Data Corporation s products the aforementioned warranty and shall indemnify and hold harmless Comtech EF Data Corporation from any claims or liability of such purchaser lessee or user based upon alleg...

Страница 20: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Preface Revision 3 xviii Notes...

Страница 21: ...y is not required Figure 1 1 Comtech EF Data LPOD R Outdoor Amplifiers BUCs 1 2 Functional Description The LPOD R serves as a more reliable replacement for Traveling Wave Tube TWT amplifiers in satell...

Страница 22: ...full 13 75 to 14 5 GHz Ku Band and 5850 to 6725 MHz C Band coverage while supporting industry standard FSK modem BUC communications as well as Comtech EF Data proprietary commands 1 3 3 Enhanced Stan...

Страница 23: ...he unit itself but also the unit s operational environment 1 3 3 3 Hand Held Controller Devices The LPOD R accommodates a variety of hand held controller devices These include the LPODnet M C Accessor...

Страница 24: ...After some amplification a second attenuator is automatically controlled via a look up table to maintain the amplifier gain at a constant level over temperature variations The RF signal is then ampli...

Страница 25: ...e power transistors within the RF module from failure due to improper power supply sequencing The 24V output powers the cooling fans is the source of power for waveguide switching when the SSPA is use...

Страница 26: ...available on the PS 1 and PS 1 5 packages The M C system monitors the fan speed unit temperature all power supply voltages power transistor currents output power etc Should a critical monitored param...

Страница 27: ...W 40 dBm 10 W PS 5 20Ku 43 dBm 20 W 42 dBm 16 W PS1 20Ku 43 dBm 20 W 42 dBm 16 W PS1 32Ku 45 dBm 32 W 44 dBm 25 W PS1 40Ku 46 dBm 40 W 45 dBm 32 W PS1 5 50Ku 47 dBm 50 W 46 dBm 40 W PS1 5 60Ku 48 dBm...

Страница 28: ...gure 15 dB typical 20 dB max min attenuation RF Mute Isolation 60 dBc min AM PM Conversion 2 typical 3 5 max Rated P1dB output power Third order Intermodulation Level 2 tones 3 dB Total Backoff from P...

Страница 29: ...1 17 lbs 9 1 kg Nominal PS1 5 Dimensions excluding connectors See Section 1 6 PS 5 7 21 x 4 65 x 3 34 in 183 1 x 118 1 x 84 8 mm PS 1 12 60 x 6 31 x 6 05 in 320 0 x 160 3 x 153 7 mm PS 1 5 12 78 x 6 1...

Страница 30: ...Dimensional Envelopes Typical for all figures in each subsection all dimensions are in inches Bracketed dimensions where shown are in metric units mm All figures depict a waveguide output unless other...

Страница 31: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 11 Figure 1 5 LPOD R PS 5 C Band 20W Unit...

Страница 32: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 12 Figure 1 6 LPOD R PS 5 Ku Band 8W Unit...

Страница 33: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 13 Figure 1 7 LPOD R PS 5 Ku Band 16W Unit...

Страница 34: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 14 1 6 2 LPOD R PS 1 Dimensional Envelopes Figure 1 8 LPOD R PS 1 C Band Unit Coaxial Output...

Страница 35: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 15 Figure 1 9 LPOD R PS 1 C Band Unit...

Страница 36: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 16 Figure 1 10 LPOD R PS 1 Ku Band Unit...

Страница 37: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 17 1 6 3 LPOD R PS 1 5 Dimensional Envelopes Figure 1 11 LPOD R PS 1 5 C Band Unit...

Страница 38: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Introduction Revision 3 1 18 Figure 1 12 LPOD R PS 1 5 Ku Band Unit...

Страница 39: ...RATION PS 1 PS 1 5 ONLY for information about using the LPOD R s optional serial based remote commands and queries This chapter provides user reference to the following The LPOD R connectors for signa...

Страница 40: ...ng must cover the external connector housing and extend beyond the end of the heatshrink that covers the connector termination of the cable assembly Squeeze the self amalgamating tape tightly and make...

Страница 41: ...on 3 2 3 2 3 LPOD R Interface Connectors The LPOD R external connectors provide all necessary connections between the LPOD R PS 5 Figure 2 1 PS 1 Figure 2 2 or PS 1 5 Figure 2 3 unit and other equipme...

Страница 42: ...RNING FOR SAFETY REASONS NEVER LOOK DIRECTLY INTO THE WAVEGUIDE OUTPUT The J2 RF OUT connector may be a waveguide or coaxial interface this depends on the LPOD R model and or frequency range of the un...

Страница 43: ...onnector specification and pin assignments specific to the LPOD R PS 1 and PS 1 5 standard AC power interfaces are as follows Mating Connector CEFD P N CN MS STPG03F02 ITT Cannon KPT06B 12 35 Table 2...

Страница 44: ...n result in product damage or personal injury For all LPOD R models the prime power input requirement is 38 72V DC The total power required from the prime power supply depends on the model in use See...

Страница 45: ...CN STPG04F01 Glenair IPT06E 12 4 SSR F7 Table 2 4 LPOD R PS 1 J3 POWER IN Pin Assignments Pin LPOD R PS 1 Assignment A V B GND C V D NO CONNECT 2 3 4 3 J3 POWER IN PS 1 5 Optional DC Power Main The m...

Страница 46: ...Connector Type Ref Des Name Direction Weatherproof RJ 45 female modular jack Samtec USA Corp P N RPBE 01 J6 COM 1 In Out CAUTION For permanent Ethernet connections you MUST use the appropriate mating...

Страница 47: ...he RJ 45 modular plug Item 2 1 onto Item 1 Be sure to maintain the cable wiring per the Note 3 wiring table 3 Snap Item 2 1 into the Ethernet Shroud Item 2 2 Then snap Item 2 2 into the Latched Housin...

Страница 48: ...R not part of kit 6 5mm OD 8 wire CAT5e Ethernet Cable 2 1 RCEF G 01 Samtec Weatherproof Connector Assembly Items 2 1 2 6 1 RCEF G 02 2 1 1 1 SUB MODP 01 8P8C S 01 RJ 45 Modular Ethernet Plug 2 2 1 1...

Страница 49: ...ignments Pin Name Description A RS485_ RX B RS485_ RX C RS485_ TX D RS485_ TX E RS232_RD Pin 3 of DB9 female connector F Ethernet TX Pin 3 of RJ 45 female connector G RS232_TD Pin 2 of DB9 female conn...

Страница 50: ...eve Lock features Figure 2 5 Circular Connector Example Connection Instructions Engage all of the alignment and lock features between the male connector on the interconnection cable and female socket...

Страница 51: ...UC MN LPODR System Connectors Installation and Startup Revision 3 2 13 2 3 7 Ground Connector Use this 10 32 stud available where shown in Figure 2 6 to connect a common chassis ground among equipment...

Страница 52: ...ered See Sect 2 4 3 for standalone assembly and installation information for pole mounted LPOD R configurations See Sect 2 4 4 for standalone assembly and installation for spar mounted LPOD R configur...

Страница 53: ...unt Kit PL 12319 1 is used in combination with pole mounted standalone installation kits For purpose of brevity all subsequent mention of this kit s usage refers you back to this chapter section CHAPT...

Страница 54: ...E BLOCK 4 2 HW M8X1 25X25HEXSS SS HEX HEAD BOLT M8 25MM LG 5 7 HW M8FLATSS SS FLAT WASHER M8 6 7 HW M8LOCKSS SS LOCK WASHER M8 7 1 FP BR0069 FLOATING STRAP BRACKET 8 1 FP BR0071 PIPE STRAP TRIM TO REQ...

Страница 55: ...washers Item 6 and hex nuts Item 9 7 Do the following a Holding the kit subassembly in place against the mounting pole slide the Fixed Strap Bracket Item 10 into the Unistrut channel until it abuts th...

Страница 56: ...ectors Installation and Startup Revision 3 2 18 The assembled kit appears as shown in the top and side view example shown in Figure 2 8 Depending on the application you may proceed to the next phase o...

Страница 57: ...h the PL 12319 1 Universal Pole Mounting Kit ITEM QTY CEFD PART NO DESCRIPTION 1 1 FP 0000534 BRACKET MOUNTING 2 1 FP BR0078 UNISTRUT DUAL CHANNEL 3 2 HW 1 4 20X1 2FH SCREW 82 FLAT HEAD PHILLIPS 1 4 2...

Страница 58: ...e configurations in addition to satellite dish support pole mounted installations may be installed on the antenna spar Figure 2 10 shows a typical Comtech EF Data spar mount SSPA installation The kit...

Страница 59: ...1 FP 0000547 BRACKET MOUNTING 1 5 x 2 0 38 1 X 50 8 SPAR 1 FP 0000546 BRACKET MOUNTING 1 75 x 4 0 44 4 X 101 6 SPAR 1 FP 0000545 BRACKET MOUNTING 1 0 x 2 5 25 4 X 63 5 SPAR 1 FP 0001330 BRACKET MOUNTI...

Страница 60: ...ITEM QTY CEFD PART NO DESCRIPTION 1 1 FP 0021719 BRACKET LOWER 2 1 FP 0021720 BRACKET UPPER 3 3 HW 8 SPLIT LOCK WASHER SPLIT 8 4 3 HW 832X5 8SHCS SOCKET HEAD CAP SCREW 8 32 X 5 8 LG 5 2 HW 5 16 18X1...

Страница 61: ...g the J3 POWER IN connector to the appropriate prime power source The Mute or Transmit status of the unit automatically comes up in the last stored state factory default Transmit on not muted 2 5 2 Mo...

Страница 62: ...ccess credentials i e the username password and SNMP communities prohibits M C of the LPOD R You can reset the access credentials for the LPOD R to the factory default settings To do this issue a ping...

Страница 63: ...unning LPOD R a Type ping t 169 254 1 1 to begin repeatedly pinging the LPOD R b Cycle the LPOD R power as the User PC continues to ping the unit c Continue to observe the ping responses in the Window...

Страница 64: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR System Connectors Installation and Startup Revision 3 2 26 Notes...

Страница 65: ...he archive file by e mail from Comtech EF Data Product Support 3 1 1 LPOD R Firmware Update Procedure Summary 1 Download the firmware update archive file to a user supplied PC The PC must be Microsoft...

Страница 66: ...are Downloads LPOD R Software Downloads The LPOD R PS 5 firmware download hyperlink appears as F0020841x_V The LPOD R PS 1 and PS 1 5 firmware download hyperlink appears as F0020880x_V Typical for eit...

Страница 67: ...ch EF Data All Current LPOD R Models See Figure 3 1 You can use Comtech s optional LPODnet part of CEFD KT 0000203 M C Netbook Accessory Kit for Ethernet based M C of the LPOD R The LPOD R features a...

Страница 68: ...port Figure 3 2 M C Utilities Available from Comtech EF Data Earlier LPOD R PS1 or PS 1 5 Models See Figure 3 2 You can use Comtech EF Data s optional CLC 10 Handheld Terminal part of CEFD M C Access...

Страница 69: ...NONE Display New Line Rx Tx CR 1 Read your terminal emulator program user guide or HELP feature for operating and configuration instructions 2 The CLC 10 Handheld Terminal may be used in place of a PC...

Страница 70: ...see Section 3 2 3 2 3 2 3 1 Use the HTTP Interface to Find the Firmware Information Chapter 4 ETHERNET INTERFACE OPERATION Do these steps 1 Go to one of these pages to review the firmware information...

Страница 71: ...M YY where FW AAAAAAA the firmware part number B B BB the firmware version number DD MM YY the firmware release date Day Month Year 3 2 4 Make a Temporary Folder Subdirectory on the User PC The tempor...

Страница 72: ...ct Rename from the popup submenu Rename this folder to temp or some other convenient unused name 3 2 4 2 Use Windows Explorer to Make a Folder Do these steps 1 Left double click the Windows Explorer i...

Страница 73: ...r folder name and then Rename this folder to temp or some other convenient unused name 3 2 4 4 Use Windows Command line or Command Prompt to Make a Folder Select Start on the Windows taskbar and then...

Страница 74: ...page Under Support Information or the Support tab select the Software Downloads hyperlink 3 On the Software Downloads page Click Download Flash and Software Update Files 4 On the Flash Updates Index...

Страница 75: ...POD R o Click Save to download the EXE file to your Downloads folder Once the download is complete the dialogue prompts you to either Run the self extracting file or to open or view the Windows Downlo...

Страница 76: ...ware revision letter and _ _ or is the firmware version e g FW Ver 1 2 3 1_2_3 or 123 9 Confirm availability of the firmware files in the temporary folder There are several ways you can view the conte...

Страница 77: ...PC Ethernet port with a CAT5e Ethernet cable Your PC is running a terminal emulation program for operation of the LPOD R Ethernet Telnet or the optional serial interfaces You have noted your LPOD R Ma...

Страница 78: ...correctly entered into CReflash the utility displays an animated progress bar at the bottom of the window along with a series of messages Opening FTP Sending data file to modem Writing FLASH of Succes...

Страница 79: ...TP session g Close the Windows Command line window 4 To verify that the PC to unit FTP file transfer was successful find the current firmware information via the HTTP or optional serial interfaces see...

Страница 80: ...t has rebooted with the new firmware if the optional serial interface is available you may clear the trending data Use the terminal emulator or CLC 10 Handheld Terminal to enter serial remote command...

Страница 81: ...Browser CAUTION Comtech EF Data recommends use of the Ethernet based SNMP interface for advanced users only All other users are strongly encouraged to use the LPOD R HTTP Interface for remote Monitor...

Страница 82: ...with the available CA 0000352 Ethernet Interface Cable part of CEFD Kit KT 0000203 You have recorded the LPOD R s Management IP Address 4 2 SNMP Interface SNMP is an Internet standard protocol for ma...

Страница 83: ...90x mib Trap MIB file provides SNMPv1 traps common for LPOD R 4 2 2 SNMP Community Strings CAUTION In SNMP v1 v2c the SNMP Community String is sent unencrypted in the SNMP packets Caution must be take...

Страница 84: ...d Write level Once logged into the Telnet interface as the Administrator you have access to the optional serial based Remote Control Interface An example of the login process and remote control operat...

Страница 85: ...l terminal emulation program configured as a Telnet client An example of the login process and remote control operation when using HyperTerminal as the interface is shown here Figure 4 2 Telnet Interf...

Страница 86: ...I Sending section b Check the Append line feeds to incoming line ends option in the ASCII Receiving section c Click OK to save your settings 4 4 HTTP Web Server Interface A user supplied web browser a...

Страница 87: ...ss of the unit s Management IP Address or the interface access credentials i e the username password and SNMP communities prohibits M C of the LPOD R Follow the procedures described in Sect 2 4 3 Reco...

Страница 88: ...HTTP Interface Splash Page PS 5 Unit Example Shown 4 4 3 HTTP Interface Features 4 4 3 1 Menu Tree Figure 4 5 shows the menus and pages in the LPOD R HTTP Interface This interface has four top level n...

Страница 89: ...scribes its operational features Each section can have editable fields action buttons and read only displays for a specific function This manual explains the purpose and operation for each Web page an...

Страница 90: ...a Entry Text boxes let you type data into a field An action button can be associated with a single text box or a group of text boxes For any text box left click anywhere inside the box and type the de...

Страница 91: ...1 Home Pages 4 5 1 1 Home Home Use this page to identify the product Click the Home navigation tab or the page hyperlink to return to this page from anywhere in the HTTP Interface Figure 4 6 LPOD R Ho...

Страница 92: ...istrator pages to set up user access Click Access or SNMP to continue 4 5 2 1 Admin Access Refresh the page to see the latest data Figure 4 7 Admin Access Page Network Maintenance IP Gateway IP Addres...

Страница 93: ...se names passwords are o Admin comtech comtech o Read Write opcenter 1234 o Read Only monitor 1234 Click Submit Access to save any changes Webpage Timeout The Webpage Timeout sets the time period that...

Страница 94: ...haracters and a length of 0 to 20 characters o Read Community String factory default is public o Write Community String factory default is private SNMP Contact Enter the contact data SNMP Name Enter t...

Страница 95: ...ier Attenuation dB Enter a valid attenuation level 00 00 to 20 00 dB in 0 25 dB steps Fault Recovery Use the drop down list to select Automatic or Manual User Mute Use the drop down list to select Ena...

Страница 96: ...y Use this page to configure additional LPOD R operating parameters Refresh the page to see the latest data Figure 4 10 Config Utility Page Date and Time Enter a date using international format in the...

Страница 97: ...the Current Active Firmware Image Next Reboot Image Use the drop down list to select the Next Reboot Image as Image 1 or 2 Click Submit to save the change Perform Soft Reboot Click Reboot Now to reboo...

Страница 98: ...mmary Page Summary read only The Summary Fault message shows OK on a green background if no faults are present If a fault exists the message changes to FAULT on a red background Should this occur look...

Страница 99: ...ee general status data for the LPOD R Unlike the pages that you must refresh manually the Status Status page updates automatically once every 10 seconds You can still refresh the page manually if desi...

Страница 100: ...sequential date stamped format The unit shows the five oldest stored events in the alarm log A running tally of the number of unread stored events shows in the window header All events that are read f...

Страница 101: ...tatistics Page Unread Stored Statistics This window shows the unread stored statistics log in sequential date stamped format This page shows a running tally of the number of unread stored statistics i...

Страница 102: ...tion Statistics Configuration Statistics Interval Enter the interval at which statistics are logged The interval is set in minutes Minimum resolution is 1 minute 001 maximum is 99 minutes 099 Default...

Страница 103: ...LPOD R Outdoor Amplifier Block Up Converter MN LPODR Ethernet Interface Operation Revision 3 4 23 4 5 4 6 Status Trending Graphs Figure 4 16 Status Trending Graphs Page Example...

Страница 104: ...sh the page to see the latest data Trending Graph Time Settings Use these controls to define the refresh intervals for the graphs Start Date mm dd yy Use the drop down list to select present or a spec...

Страница 105: ...eir associated remote commands and queries and provides detailed instructions for use of the optional serial remote control commands and queries interface Optional serial based remote management of Co...

Страница 106: ...2 Attenuator Control The SSPA BUC gain can be attenuated over its specified range by exercising the ATT command The details for the format of this command are found later in this section 5 2 3 Mute Co...

Страница 107: ...ys current alarm or fault status 5 3 Remote Control Protocol and Structure The LPOD R SSPA BUC supports the command protocol over a Telnet session through the use of a 10 100Base T Ethernet connection...

Страница 108: ...xample 0123 MUT 1 CR Target to Controller Start of Packet Target Address Address Delimiter Instruction Code Code Qualifier Optional Arguments End of Packet ASCII code 62 1 character 0 9 ASCII codes 48...

Страница 109: ...lifies the preceding instruction code Instruction Code Qualifiers obey specific rules 5 3 2 6 Controller to Target Rules From Controller to Target the permitted qualifiers are or ASCII codes 61 or 63...

Страница 110: ...oing the invalid instruction followed by this character For example 0001 XYZ CR LF ASCII code 42 displays when the Controller sends a command to set a parameter s value and the value is valid but the...

Страница 111: ...messages Arguments include these ASCII codes Characters 0 through 9 ASCII codes 48 through 57 Period ASCII code 46 Comma ASCII code 44 5 3 2 9 End of Packet Controller to Target This is the Carriage R...

Страница 112: ...r Threshold 5 16 MAC Address 5 16 Management IP Address 5 15 Mute State 5 16 Number of Unread Events 5 16 Number of Unread Statistics 5 17 Part Number 5 17 Reboot Command 5 18 Remote Address 5 23 Retr...

Страница 113: ...isabled the output will remain muted even if all faults are cleared COMMAND EXAMPLE 0001 AFR 1 CR AFR AFR AFR AFR x RF Power Amplifier State AMP AMP 1 byte Command or Query Sets turns ON or OFF or ret...

Страница 114: ...f g h i j k I m n o p q r s t u v w x y z where a thru z 0 1 2 3 4 or 5 0 FT 1 OK 2 AL 3 NO 4 YS 5 MS a 24V Power Supply b 24V Power Supply NOT USED c 13 18V LNB Power Supply NOT USED d 13 5V Power S...

Страница 115: ...NOT USED e Redundancy state and mode NOT USED ff ff Attenuator offset in dB NOT USED g auto fault recovery mode AFR hhh External reference status NOT USED NOTE This is the condensed version of the RCS...

Страница 116: ...e P10V1 fff f A10V1 ggg g A10V2 NOT USED hhh h P7V8T iii i P5V8T jjj j P2V5T kkk k P1V2T lll l N5V8T mmm m FANR1 nnn n FANR2 PS 1 5 ONLY ooo o BUCVT ONLY WHEN BUC OPTION INSTALLED ppp p FWPWR qqq q R...

Страница 117: ...s in the form x where 0 Disable DEFAULT 1 Enable NOTE If Disabled burst values will be logged instead of averaged values COMMAND EXAMPLE 0001 ESA 0 CR ESA ESA ESA ESA x Retrieve Firmware Number N A FR...

Страница 118: ...le NOT USED j Enable Statistics Averaging ESA k Set Statistics Interval SSI l Enable Statistics Logging NOT USED m Auxiliary Mute NOT USED n user mute state MUT o RF power amplifier state AMP GAC GAC...

Страница 119: ...xx xxx yy Gateway IP Address IPG IPG 15 bytes Command or Query Sets or returns the Gateway IP Address for the J6 COM1 10 100 Base Tx Ethernet management port in the form xxx xxx xxx xxx where xxx xxx...

Страница 120: ...itions in the form abcde where 0 Fault 1 Alarm 2 Masked a Low Forward RF Power b External Reference Lock detect c Fan Speed d LNB Current Detect NOT USED e LNB 22V Power Supply NOT USED NOTES 1 Defaul...

Страница 121: ...only Returns the Alarm status of the unit where OK No fault condition FT Faulted AL Alarm YS Yes NO No MS Masked EXAMPLE 0001 RAS CR 0001 RAS CR P24V1 OK CR 24V power supply P24V2 NA CR 24V switch po...

Страница 122: ...s the configuration status of the unit in detailed format where ATT attenuation in dB AMP RF power amplifier state where 0 OFF 1 ON MUT RF mute state where 0 Unmuted 1 Muted ONL Online status for redu...

Страница 123: ...cription of Arguments Command Query Response to Command Response to Query RF Power FET current Status N A RFS Length varies depending on the number of installed FETs Query only Returns currents for al...

Страница 124: ...pply A10V1 10V1 on RF Module A10V2 10V2 on RF Module NOT USED P7V8T 7 8V power supply P5V8T 5 8V power supply P2V5T 2 5V power supply N1V2T 1 2V power supply N5V8T 5 8V power supply FANR1 Fan 1 speed...

Страница 125: ...ault type 1 Unit 2 RF 3 Log CC Fault Code numbers as in RAS or Info Codes RAS FAULT CODES MAP AS FOLLOWS 1 P24V1 2 P13VT 3 A10V1 4 A10VPS 5 P5V8T 6 P2V5T 7 P1V2T 8 N5V8T 9 P7V8T 10 FANR1 11 FANR2 PS 1...

Страница 126: ...Off g Online Offline Status NOT USED hhh h LNB Current mA NOT USED iii i BUC Tuning Voltage VALID ONLY WHEN OPTIONAL BUC IS INSTALLED NOTES 1 If less than 5 entries are retrieved the remaining positi...

Страница 127: ...blic CR SRC SRC SRC x SNMP System Contact SSC SSC 255 bytes characters Command or Query Sets or returns the SNMP System Contact string COMMAND EXAMPLE 0001 SSC Joe Net Admin CR NOTE When not configure...

Страница 128: ...y Sets or returns the SNMP Write Community string COMMAND EXAMPLE 0001 SWC private CR NOTE An empty string is not allowed SWC SWC SWC x Software Revision N A SWR 34 37 bytes Query only Returns the val...

Страница 129: ...hange has occurred NOTES 1 A status change is defined as any time a parameter is changed e g when a command is successfully executed that changes a value A status change also results when there is a f...

Страница 130: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Optional Serial Interface Operation PS 1 PS 1 5 ONLY Revision 3 5 26 Notes...

Страница 131: ...cle to the CLC 10 RJ 11 comms jack Cable and CLC 10 are furnished as part of optional CEFD KIT KT 0020518 A 2 CA 0000352 Ethernet Interface Cable 19 pin circular connector to 2X RJ 45 Connecting a sta...

Страница 132: ...The optional Comtech EF Data CLC 10 Serial M C Accessory Kit CEFD P N KT 0020518 includes the CA 0020526 Serial Interface Cable This kit is available to provide optional serial based M C of standalone...

Страница 133: ...a weatherproof RJ 45 Ethernet receptacle providing Ethernet based M C The optional Comtech EF Data Ethernet Utility Kit CEFD P N KT 0000203 includes the LPODnet a Samsung NB30 Plus Netbook and the CA...

Страница 134: ...or a user PC It is recommended for use only in temporary applications CAUTION For permanent Ethernet data connections you MUST use the appropriate mating connector on your supplied Ethernet cable to e...

Страница 135: ...onverter BUC MN LPODR Appendix A Revision 3 A 5 A 3 RF Cables Figure CEFD CABLE P N DESCRIPTION USED FOR A 4 CA 3722 X Type N to Type N 1 4 Heliax Coaxial Cable lengths vary LPOD R Rx or Tx connection...

Страница 136: ...R standalone or future 1 1 Redundancy applications For all LPOD R standalone applications This cable connects directly from the Tx signal source to the J1 L BAND IN LPOD interface For LPOD R PS 1 C Ba...

Страница 137: ...re designed for long life even in harsh environments Still they are mechanical devices subject to wear and may need replacement after several years In most environments Comtech EF Data recommends clea...

Страница 138: ...the cover plate to access the fan assembly see Figure B 4 4 CAUTION Carefully set aside the fan assembly Make sure not to crimp or otherwise damage the fan s power supply wiring see Figure B 5 5 Visua...

Страница 139: ...cover plate onto the chassis see Figure B 8 make sure to keep the fan power supply wiring clear of the cover plate surfaces Then re install the four cover screws as described in Step 2 Torque the scre...

Страница 140: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 4 Figure B 4 Remove the Cover Plate...

Страница 141: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 5 Figure B 5 Set Aside the Fan Assembly Figure B 6 LPOD R PS 5 Heat Sink Locations Fan Not Shown for Clarity...

Страница 142: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 6 Figure B 7 Reseat the Fan Assembly Figure B 8 Replace the Cover Plate...

Страница 143: ...hen pull apart the mated components see Figure B 11 5 Visually inspect the exposed LPOD R heat sinks located on the top and either side of the chassis for any accumulated debris or blockage that may b...

Страница 144: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 8 Figure B 9 LPOD R PS 1 Shroud Screw Locations Figure B 10 Remove the Fan Shroud...

Страница 145: ...Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 9 Figure B 11 Disconnect the Fan Power Supply Figure B 12 LPOD R PS 1 Heat Sink Locations Figure B 13 Reconnect the Fan Power...

Страница 146: ...ctions see Figure B 15 4 Disconnect each fan power supply by carefully pulling the mated connector components straight apart see Figure B 16 Do not twist the mated cable connection when disconnecting...

Страница 147: ...s Make sure to keep the fan power supply cables clear of the fan and heat sink surfaces Then re install all screws as described in Step 2 making sure to re install the four longer screws at their same...

Страница 148: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 12 Figure B 15 Remove the Fan Shroud Figure B 16 Disconnect the Fan 1 Fan 2 Power Supplies...

Страница 149: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 13 Figure B 17 LPOD R PS 1 5 Heat Sink Location Figure B 18 Reconnect the Fan 1 Fan 2 Power Supplies...

Страница 150: ...xternal cable assemblies for the outdoor equipment are properly sealed to prevent water intrusion Failure to achieve water tight sealing will result in possible performance degradation and even produc...

Страница 151: ......

Страница 152: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...

Отзывы: