Parameter Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of Arguments)
Command
Query
Response to
Command
Response to
Query
SNMP Enable
SNM=
SNM?
1 byte
Command or Query.
Sets or returns SNMP in the form x, where:
0 = Disabled
1 = Enabled
COMMAND EXAMPLE:
<0001/SNM=0{CR}
SNM=
SNM?
SNM=x
Serial Number*
N/A
SNO?
9 bytes
Query only.
Returns the unit’s nine-digit serial number in the form xxxxxxxxx.
NOTE:
This query is functionally identical to RSN.
EXAMPLE:
<0001/SNO?{CR}
>0001/SNO=012345678{CR}{LF}
SNO=
SNO=xxxxxxxxx
Set Physical
(remote) Address
SPA=
SPA?
4 bytes
Command or Query.
Sets or returns the Physical Address in the form xxxx where:
xxxx = Address value from 0001 (
DEFAULT
) to 9999.
COMMAND EXAMPLE:
<0001/SPA=0412{CR}
SPA=
SPA?
SPA*
SPA=xxxx
SNMP Read
Community
SRC=
SRC?
16 bytes,
characters, no
spaces
Command or Query.
Sets or returns the SNMP Read Community string.
NOTE:
An empty string is not allowed.
COMMAND EXAMPLE:
<0001/SRC=public{CR}
SRC =
SRC!
SRC=x
SNMP System
Contact
SSC=
SSC?
255 bytes,
characters,
Command or Query.
Sets or returns the SNMP System Contact string.
COMMAND EXAMPLE:
<0001/SSC=Joe Net Admin{CR}
NOTE:
When not configured, the Target returns an empty string: <0001/SSC={CR}{LF}
SSC =
SSC!
SSC=x [1..128]
Set Statistics
Interval
SSI=
SSI?
2 bytes
Command or Query.
Sets or returns the time interval, in minutes, at which statistics are logged in the form xx, where:
xx = interval, from 01 to 99 minutes (see NOTE)
NOTE:
Default value is 90 minutes.
COMMAN D EXAMPLE:
<0001/SSI=90{CR}
SSI=
SSI?
SSI=xx
SNMP System
Location
SSL=
SSL?
255 bytes,
characters,
Command or Query.
Sets or returns the SNMP System Location string.
COMMAND EXAMPLE:
<0001/SSL=Upstairs back right.
NOTE:
When not configured, the Target returns an empty string. <0001/SSL={CR}{LF}
SSL =
SSL!
SSL=x[1..128]
SNMP Unit Name SSN=
SSN?
16 bytes,
characters,
Command or Query.
Sets or returns the SNMP Unit Name string.
COMMAND EXAMPLE:
<0001/SSN=Remote1{CR}
NOTE:
When not configured, the Target returns an empty string. <0001/SSC={CR}{LF}
SSN =
SSN!
SSN=x[1..128]
SNMP Trap
Destination IP
Address 1
STA=
STA?
15 bytes,
Numerical
Command or Query.
Sets or returns the IP Address of the SNMP Trap Destination IP Address 1 (where
traps will be sent first) in the form xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx = IP Address
COMMAND EXAMPLE:
<0001/STA=010.006.030.001{CR}
NOTE:
When not configured, the Target returns >0001/STA=0.0.0.0{CR}{LF}
STA =
STA!
STA=xxx.xxx.xx
x.xxx
Содержание LPOD-R PS .5
Страница 4: ...ER LPODR EA3 Rev 2 Blank Page...
Страница 20: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Preface Revision 3 xviii Notes...
Страница 140: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 4 Figure B 4 Remove the Cover Plate...
Страница 151: ......
Страница 152: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...