LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial Interface Operation (PS 1, PS 1.5 ONLY)
Revision 3
5–19
Parameter Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of Arguments)
Command
Query
Response to
Command
Response to
Query
RF Power FET
current Status
N/A
RFS?
Length varies
depending on
the number of
installed FETs
Query only.
Returns currents for all installed FETs.
EXAMPLE:
<0001/RFS? {CR}
>0001/RFS={CR}
Q01=.xxx{CR}
Q02=.xxx{CR}
Q03=xx.x{CR}
Q04=xx.x{CR}
Q05=xx.x{CR}
Q06=xx.x{CR}
Q07=xx.x{CR}
Q08=xx.x{CR}
Q09=xx.x{CR}
Q10=xx.x{CR}
Q11 = xx.x{CR}
Q12=xx.x{CR}
Q13=xx.x{CR}
Q14=xx.x{CR}
Q15=xx.x{CR}
Q16=xx.x{CR}{LF}
NOTE:
If the reported value is one amp or greater, the format is xx.x; if the value is less than one amp, the format
is .xxx
RFS=
RFS=x….x