LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
System Connectors, Installation, and Startup
Revision 3
2–5
2.3.3
‘J3 | POWER IN’ AC Power Main (PS 1, PS 1.5 ONLY)
WARNING!
1)
The LPOD PS .5 is available only as a DC unit.
2)
For safety reasons, you must use the correct pin assignments.
Incorrect use of pin assignments can result in product damage or
personal injury.
The mating connector specification and pin assignments specific
to the LPOD-R PS 1 and PS 1.5 standard AC power interfaces are
as follows:
Mating Connector:
CEFD P/N CN/MS-STPG03F02 (ITT Cannon KPT06B-12-35)
Table 2-2. LPOD-R PS 1, PS 1.5 ‘J3 | POWER IN’ Pin Assignments
Pin
Description
A
LINE (L1)
B
NEUTRAL (L2)
C
GND
The prime power input requirement for the LPOD-R PS 1 and PS 1.5 is as follows:
•
90-264V AC
•
47-63 Hz
The power supply is power factor corrected. The total power required from the
prime power supply depends on the model used. See
Sect. 1.5 Summary of
Specifications
for more information.