LPOD-R Outdoor Amplifier / Block Up Converter
MN-LPODR
Ethernet Interface Operation
Revision 3
4–15
4.5.3
Config Pages
Use the
Configuration
pages to configure all operating parameters for the
LPOD-R. Click
Amplifier
or
Utility
to continue,
4.5.3.1
Config | Amplifier
Use this page to configure the communications, operations and alarms/faults
handling for the amplifier. Refresh the page to see the latest data.
Figure 4-9. Config | Amplifier Page
Amplifier
•
Attenuation (dB)
– Enter a valid attenuation level (
00.00
to
20.00
dB) in
0.25 dB steps.
•
Fault Recovery
– Use the drop-down list to select
Automatic
or
Manual
.
•
User Mute
– Use the drop-down list to select
Enabled
or
Disabled
.
Click
Change Configuration
to save any changes.
Low Forward Power Threshold (dBm)
Set the threshold value, in dBm, for the low forward power alarm/fault.
When the forward power monitor is set to
Alarm
or
Fault
instead of the factory
default of
Mask
, and the forward power drops below the specified value, the
alarm/fault occurs.
To disable the threshold, set this parameter to the default value of 00.00.
Click
Change
to save any changes.
Содержание LPOD-R PS .5
Страница 4: ...ER LPODR EA3 Rev 2 Blank Page...
Страница 20: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Preface Revision 3 xviii Notes...
Страница 140: ...LPOD R Outdoor Amplifier Block Up Converter BUC MN LPODR Appendix B Revision 3 B 4 Figure B 4 Remove the Cover Plate...
Страница 151: ......
Страница 152: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...