LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
System Connectors, Installation, and Startup
Revision 3
2–6
2.3.4
‘J3 | POWER IN’ Standard or Optional DC Power
Mains
WARNING!
For safety reasons, make sure you know that the ‘J3 | POWER IN’ DC
power connection pin assignments are DIFFERENT for each LPOD unit.
You must use the correct pin assignments. Incorrect use of pin
assignments can result in product damage or personal injury.
For all LPOD-R models, the prime power input requirement is 38-72V DC. The
total power required from the prime power supply depends on the model in use.
See
Sect. 1.5 Summary of Specifications
for more information.
2.3.4.1
‘J3 | POWER IN’ – PS .5 Standard DC Power Main
The mating connector specification and the pin assignments
specific to the LPOD-R PS .5 standard DC power interface are as
follows:
Mating Connector:
CEFD P/N CN-0020708 (SOURIAU UTS6JC8E33S)
Table 2-3. LPOD-R PS .5 ‘J3 | POWER IN’ Pin Assignments
Pin
LPOD-R PS 1 Assignment
A
V+
B
V-
C
GND