ID-Mobile Global Guide
91
Setpoint group
Engine protection
Related FW
2.6.0
Range [units]
0 .. 60 [s]
Default value
1
Step
1 s
Comm object
10131
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Binary input protection is activated when input is closed for longer time than BinInp delay 1. To use this filter
Binary input must be configured in DriveConfig for Property – Delay = BinInp delay 1.
BinInp Delay 1
Setpoint group
Engine protection
Related FW
2.6.0
Range [units]
0 .. 60 [s]
Default value
5
Step
1 s
Comm object
10132
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Binary input protection is activated when input is closed for longer time than BinInp delay 2. To use this filter
Binary input must be configured in DriveConfig for Property – Delay = BinInp delay 2.
BinInp Delay 2