ID-Mobile Global Guide
29
2.8.5 Low and High limit explanation
2.8.6 Transformed output value indication
The „&” prefix is used with Source value name for output value indication in corresponding analog inputs.
2.8.7 PWM output on BO9 up to BO16
Dither function is intended to avoid an unpredictable behavior of hydraulic proportional valves caused by
hysteresis and stiction. Dither is a rapid, small movement of the spool around desire position which eliminates
the stiction and enables more accurate moving of the valve.