ID-Mobile Global Guide
13
2.2.2 Assembling
Settle the silicone sealing and be sure the sealing is undamaged
Fit the controller case and cover so that both parts are matching
properly in joint shells
Firstly screw up all bolts but do not finalize
Finalize all bolts with the sequence as shown below.
The maximum
torque is 1 Nm
2.3 Harnesses
All signals are connected via two MOLEX CMC (4×12) 48
pins connectors. Bold (power) items are connected via
MOLEX CMC stronger pins with wires crosscut about 1.5
mm
2
.
Harness Lenght
ComAp Order Code
1.5. meters
ID-Mobile Harness-1.5
6 meters
ID-Mobile Harness-6
Sets of
harnesses
left and right connector
cables, interconnection
cable sleeve
Available standard harnesses supplied by ComAp
Note:
Harnesses for ID-Mobile Logger are not compatible with ID-Mobile control unit.