ID-Mobile Global Guide
257
Counter
Symbol
Inputs
Input
Type
Range[DIM]
Function
Input Cnt
B
N/A
Input at which the edges
are counted
Input Lim
A
0..32767 [-]
Counter value limit for
activation of the output
Input Clr
B
N/A
Reset input
Outputs
Output
Type
Range[DIM]
Function
Output
B
N/A
Output is activated when
the counter value exceeds
the limit
Description
The block works as a counter of edges (selectable rising, falling or both) with reset input and
adjustable counting limit. The maximal counter value is 32767. The counter value is lost
when the controller is switched off. The output is activated when the counter value reaches
equal or higher value than the adjusted limit and remain active until the block is reset.
Activating of the reset input resets the counter value to 0, deactivates the output. Holding the
reset input active blocks counting.
1. Adjust limit value. The counter output is activated when the counter gets over this
value. The limit can be constant as well as a setpoint or any other analog value.
2. Rename the output.
3. Select edges which will be counted.
Note:
The inputs are assigned to their sources in the sheet by
dragging a wire
from the
input to the source.