GR716-DS-UM, May 2019, Version 1.29
457
www.cobham.com/gaisler
GR716
45.8.6
Table 616.
0x14 - INTE- Interrupt enable register
Interrupt Enable Register
r
31 : 0
Redundant Receive data (RRDATA) - This register contains received data from the redundant port.
Valid only for SPI protocol 0 and 1.
31
24
23
8
7
6
5
4
3
2
1
0
Key
RESERVED
WDE
AE
CRE
CWE
TICKE SYNCE RXRE
RXNE
0
0
0
0
0
0
0
0
0
0
w
r
rw
rw
rw
rw
rw
rw
rw
rw
31 : 24
Safety code (KEY) - Must be 0x68 when writing, otherwise register write is ignored.
23 : 8
RESERVED (R) - Read as zero and should be written to zero to ensure forward compatibility.
7
Write data interrupt enable (
WDE
). Valid only for SPI protocol 2.
6
AMBA access error interrupt enable (AE). Valid only for SPI protocol 2.
5
Change in config read address interrupt enable (CRE). Valid only for SPI protocol 2.
4
Change in config write address interrupt enable (CWE). Valid only for SPI protocol 2.
3
Tick command received interrupt enable (TICKE). Valid only for SPI protocol 2.
2
Sync command received interrupt enable (SYNCE). Valid only for SPI protocol 2.
1
Data received in redundant port interrupt enable (RXRE).Valid only for SPI protocol 0 and 1.
0
Data received in nominal port interrupt enable (RXNE). Valid only for SPI protocol 0 and 1.
Table 615.
0x10 - RRDATA - Redundant receive register