GR716-DS-UM, May 2019, Version 1.29
358
www.cobham.com/gaisler
GR716
34.6.18
Table 458.
0x054 - DET4 - Datation Elapsed Time 4
Datation Elapsed Time 4
34.6.19
Table 459.
0x060 - TRPFRx - Time-Stamp Preamble Field Rx
Time-Stamp Preamble Field Rx
34.6.20
Table 460.
0x064 - TR0 - Time Stamp Elapsed Time 0 Rx
Time Stamp Elapsed Time 0 Rx
34.6.21
Table 461.
0x068 - TR1 - Time Stamp Elapsed Time 1 Rx
Time Stamp Elapsed Time 1 Rx
34.6.22
Table 462.
0x06C - TR2 - Time Stamp Elapsed Time 2 Rx
Time Stamp Elapsed Time 2 Rx
31
24 23
0
DET4
RESERVED
0
0
r
r
31: 24
DET4
Datation Elapsed Time 4
CCSDS Time Code value (128 to 135) of local ET counter value.
23: 0
RESERVED
31
16 15
0
RESERVED
TRPF
0
0x2F00
r
r
31: 16
RESERVED
15: 0
TRPF
Time stamp Preamble Field
The number of coarse and fine time implemented can be obtained from this Pre-
amble Field.
31
0
TR0
0
r
31: 0
TR0
Time stamped local ET value (0 To 31) when distributed interrupt received.
31
0
TR1
0
r
31: 0
TR1
Time stamped local ET value (32 to 63) when distributed interrupt received.
31
0
TR2
0
r
31: 0
TR2
Time stamped local ET value (64 to 95) when distributed interrupt received.