23.7.26
Table 215.
0xC4 - BMC - GR1553B BM Control register
BM Control Register
23.7.27
Table 216.
0xC8 - BMRTAF - GR1553B BM RT Address filter register
BMRT Address Filter Register
23.7.28
Table 217.
0xCC - BMRTSF - GR1553B BM RT Sub address filter register
BMRT Sub address Filter Register
31
16
15
6
5
4
3
2
1
0
BMKEY
RESERVED
WRSTP EXST
IMCL
UDWL
MANL
BMEN
0
0
0
0
0
0
0
0
rw
r
rw
rw
rw
rw
rw
rw
31 : 16
Safety key - If extra safety keys are enabled (see KEYEN), this field must be 0x1543 for a write to be
accepted. Is 0x0000 when read.
5
Wrap stop (WRSTP) - If set to ‘1’, BMEN will be set to ‘0’ and stop the BM when the BM log position wraps
around from buffer end to buffer start
4
External sync start (EXST) - If set to ‘1’,BMEN will be set to ‘1’ and the BM is started when an external BC
sync pulse is received
3
Invalid mode code log (IMCL) - Set to ‘1’ to log invalid or reserved mode codes.
2
Unexpected data word logging (UDWL) - Set to ‘1’ to log data words not seeming to be part of any command
1
Manchester/parity error logging (MANL) - Set to ‘1’ to log bit decoding errors
0
BM Enable (BMEN) - Must be set to ‘1’ to enable any BM logging
31
0
ADDRESS FILTER MASK
0xFFFFFFFF
rw
31
Enables logging of broadcast transfers
30 : 0
Each bit position set to ‘1’ enables logging of transfers with the corresponding RT address
31
0
SUBADDRESS FILTER MASK
0xFFFFFFFF
rw
31
Enables logging of mode commands on sub address 31
30 : 1
Each bit position set to ‘1’ enables logging of transfers with the corresponding RT sub address
0
Enables logging of mode commands on sub address 0