GR716-DS-UM, May 2019, Version 1.29
407
www.cobham.com/gaisler
GR716
Table 540.
0x80002110 - TCNT1 - Interrupt Timestamp 1 Counter register
31
0
TCNT
0
r
31:0
Timestamp Counter (TCNT) - Current value of timestamp counter. The counter increments when-
ever a TSISEL field in a Timestamp Control Register is non-zero. The counter will wrap to zero
upon overflow and is read only.
Table 541.
0x80002120 - TCNT2 - Interrupt Timestamp 2 Counter register
31
0
TCNT
0
r
31:0
Timestamp Counter (TCNT) - Current value of timestamp counter. The counter increments when-
ever a TSISEL field in a Timestamp Control Register is non-zero. The counter will wrap to zero
upon overflow and is read only.
Table 542.
0x80002130 - TCNT3 - Interrupt Timestamp 3 Counter register
31
0
TCNT
0
r
31:0
Timestamp Counter (TCNT) - Current value of timestamp counter. The counter increments when-
ever a TSISEL field in a Timestamp Control Register is non-zero. The counter will wrap to zero
upon overflow and is read only.