GR716-DS-UM, May 2019, Version 1.29
145
www.cobham.com/gaisler
GR716
18.7.1 UART Data Register
Table 131.
0x00 - DATA - UART data register
18.7.2 UART Status Register
Table 132.
0x04 - STAT - UART status register
31
8
7
0
RESERVED
DATA
NR
rw
7: 0
Receiver FIFO (read access)
7: 0
Transmitter FIFO (write access)
31
26 25
20 19
11 10
9
8
7
6
5
4
3
2
1
0
RCNT
TCNT
RESERVED
RF TF RH TH FE PE OV BR TE TS DR
0
0
0
0
0
0
0
0
0
0
0
1
1
0
r
r
r
r
r
r
r
rw rw rw rw
r
r
r
31: 26
Receiver FIFO count (RCNT) - shows the number of data frames in the receiver FIFO. Reset: 0
25: 20
Transmitter FIFO count (TCNT) - shows the number of data frames in the transmitter FIFO. Reset: 0
10
Receiver FIFO full (RF) - indicates that the Receiver FIFO is full. Reset: 0
9
Transmitter FIFO full (TF) - indicates that the Transmitter FIFO is full. Reset: 0
8
Receiver FIFO half-full (RH) -indicates that at least half of the FIFO is holding data. Reset: 0
7
Transmitter FIFO half-full (TH) - indicates that the FIFO is less than half-full. Reset: 0
6
Framing error (FE) - indicates that a framing error was detected. Reset: 0
5
Parity error (PE) - indicates that a parity error was detected. Reset: 0
4
Overrun (OV) - indicates that one or more character have been lost due to overrun. Reset: 0
3
Break received (BR) - indicates that a BREAK has been received. Reset: 0
2
Transmitter FIFO empty (TE) - indicates that the transmitter FIFO is empty. Reset: 1
1
Transmitter shift register empty (TS) - indicates that the transmitter shift register is empty. Reset: 1
0
Data ready (DR) - indicates that new data is available in the receiver FIFO. Reset: 0