GR716-DS-UM, May 2019, Version 1.29
327
www.cobham.com/gaisler
GR716
5
Promiscuous Mode (PM) - Enable promiscuous mode. See section 33.6.10.
4
Tick In (TI) - The host can generate a tick by writing a one to this bit. This incrementd the timer
counter (TC.TIMECNT), and the new value is transmitted. This bit will stay high until the time-code
has been sent. Note that the link interface must be in run-state for the time-code to be sent.
3
Interrupt Enable (IE) - If set, AMBA interrupt generation is enabled for the events that are individu-
ally maskable by the CTRL.TQ, CTRL.LI, INTCTRL.IQ, INTCTRL.AQ, and INTCTRL.TQ bits.
2
Autostart (AS) - Automatically start the link when a NULL has been received. Reset value is ’1’ if
the boot strap signals are configured for SpaceWire RMAP enable, see section 3.1, otherwise the
reset value is ’0’.
1
Link Start (LS) - Start the link, i.e. allow a transition from ready-state to started-state.
0
Link Disable (LD) - Disable the SpaceWire codec.
Table 401.
0x00 - CTRL - Control