![Cisco Small Business 300 1.1 Series Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/cisco/small-business-300-1-1-series/small-business-300-1-1-series_administration-manual_2609294099.webp)
Clock Commands
78-20269-01 Command Line Interface Reference Guide
100
6
Default Configuration
Offsets are 0.
Acronym is empty.
Command Mode
Global Configuration mode
User Guidelines
The system internally keeps time in UTC, so this command is used only for display
purposes and when the time is manually set.
Example
console(config)#
clock timezone
abc +2 minutes 32
6.4
clock summer-time
Use one of the formats of the clock summer-time Global Configuration command
to configure the system to automatically switch to summer time (Daylight Saving
Time). Use the no form of this command to configure the software not to
automatically switch to summer time.
Syntax
clock summer-time
zone recurring {usa | eu | {week day month hh:mm week day
month hh:mm}} [offset]
clock summer-time
zone date day month year hh:mm date month year hh:mm
[offset]
clock summer-time
zone date month day year hh:mm month day year hh:mm
[offset]
no clock summer-time
Parameters
•
zone—The acronym of the time zone to be displayed when summer time is
in effect. (Range: up to 4 characters)