![Cisco Small Business 300 1.1 Series Скачать руководство пользователя страница 239](http://html.mh-extra.com/html/cisco/small-business-300-1-1-series/small-business-300-1-1-series_administration-manual_2609294239.webp)
Remote Network Monitoring (RMON) Commands
78-20269-01 Command Line Interface Reference Guide
240
19
Syntax
rmon alarm
index mib-object-id interval rthreshold fthreshold revent fevent [type
{absolute | delta}]
[startup {rising | rising-falling | falling}] [owner name]
no rmon alarm
index
Parameters
•
index—Specifies the alarm index. (Range: 1–65535)
•
mib-object-id—Specifies the object identifier of the variable to be sampled.
(Valid OID)
•
interval—Specifies the interval in seconds during which the data is
sampled and compared with rising and falling thresholds. (Range:
1–4294967295)
•
rthreshold—Specifies the rising threshold value. (Range: 0–4294967295)
•
fthreshold—Specifies the falling threshold value. (Range: 0–4294967295)
•
revent—Specifies the index of the event triggered when a rising threshold
is crossed. (Range: 0–65535)
•
fevent—Specifies the index of the event triggered when a falling threshold
is crossed. (Range: 0–65535)
•
type {absolute | delta}—Specifies the method used for sampling the
selected variable and calculating the value to be compared against the
thresholds. The possible values are:
-
absolute—Specifies that the selected variable value is compared
directly with the thresholds at the end of the sampling interval.
-
delta—Specifies that the selected variable value of the last sample is
subtracted from the current value, and the difference is compared with
the thresholds.
•
startup {rising | rising-falling | falling}—Specifies the alarm that may be sent
when this entry becomes valid. The possible values are:
-
rising—Specifies that if the first sample (after this entry becomes valid)
is greater than or equal to rthreshold, a single rising alarm is generated.
-
rising-falling—Specifies that if the first sample (after this entry becomes
valid) is greater than or equal to
rthreshold
, a single rising alarm is
Содержание Small Business 300 1.1 Series
Страница 1: ...Cisco Small Business 300 1 1 Series Managed Switch Administration Guide CLI GUIDE ...
Страница 527: ...DHCP Relay Commands 78 20269 01 Command Line Interface Reference Guide 528 38 Servers 1 1 1 1 2 2 2 2 ...
Страница 705: ...Revision History 78 20269 01 Command Line Interface Reference Guide 936 4 ...