S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
1-40
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Switching Modules
LEDs on the Generation 1 Switching Module
Table 1-14
describes the LEDs for the 16-port and 32-port switching modules.
The Fibre Channel switching modules provide autoconfiguring Fibre Channel ports that support Fibre
Channel speeds of 1.0625 Gbps and 2.125 Gbps. For more information about supported port types, see
the
Cisco MDS 9000 Family CLI Configuration Guide
.
Table 1-14
LEDs for the Cisco MDS 9000 Family Generation 1 Fibre Channel Switching Modules
LED
Status
Description
Status
Green
All diagnostics pass. The module is operational
(normal initialization sequence).
Orange
One of the following occurs or occurred:
•
The module is booting or running diagnostics
(normal initialization sequence).
•
The inlet air temperature of the system has
exceeded the maximum system operating
temperature limit (a minor environmental
warning). To ensure maximum product life, you
should immediately correct the environmental
temperature and restore the system to normal
operation.
Red
One of the following occurs or occurred:
•
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
•
T
he inlet air temperature of the system has
exceeded the safe operating temperature limits of
the card (a major environmental warning). The
card has been shut down to prevent permanent
damage.
Speed
On
2-Gbps mode.
Off
1-Gbps mode.
Steady
flashing green
Link is up (beacon used to identify port).
1
1.
The flashing green light turns on automatically when an external loopback is detected that causes
the interfaces to be isolated. The flashing green light overrides the beacon mode configuration.
The state of the LED is restored to reflect the beacon mode configuration after the external
loopback is removed.
Link
Solid green
Link is up.
Intermittent
flashing green
Link is up (traffic on port).
Solid yellow
Link is disabled by software.
Flashing
yellow
A fault condition exists.
Off
No link.