Chapter 2 Installing the Cisco MDS 9500 Series
Installing the Chassis in a Cabinet or Rack
Figure 2-7
Installing the Cisco MDS 9509 Chassis in the Rack
Step 5
If you are installing the optional cable management bracket, place the cable management bracket in front
of the front right rack-mount brackets. Align the holes in the cable management brackets with the holes
in the front rack-mount brackets and mounting rails, and then insert the screws.
Note
Because the fan tray is on the left side of the chassis, Cisco recommends using only the right
side for cable management. Using the right side for cable management allows easy removal of
the fan tray if you need to replace a fan.
Step 6
Align the holes in the front rack-mount bracket with the holes in the mounting rails and insert the 12-24
x 3/4-inch or 10-32 x 3/4-inch screws (see
Figure 2-8
), using six screws per side.
Note
Use a minimum of six screws per side to ensure that the switch is adequately supported.
1
3
2
90022
1
Crossbar
3
Side rack-mount bracket
2
Mounting rail