S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
2-80
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing Clock Modules
•
OUTPUT FAIL LED is off.
Removing a Clock Module from the Cisco MDS 9509 Director
Before installing the clock module, check the contents of your kit.
Table 2-6
lists the contents of the
clock module replacement kit, part number DS-C9509-CL=.
These tools are required to remove or install a clock module:
•
Number 1 Phillips screwdriver
•
Your own ESD-prevention equipment or the disposable grounding wrist strap included with all
upgrade kits, field-replaceable units (FRUs), and spares
Clock modules are connected to the rear of the Cisco MDS 9509 Director using two connectors.
Figure 2-43
shows the clock modules in a rear view of the Cisco MDS 9509 Director with the back panel
removed.
Figure 2-43
Clock Module Location on the Cisco MDS 9509 Director (Rear View)
Table 2-6
Contents of Cisco MDS 9509 Clock Module Replacement Kits
Quantity
Part Description
1
Cisco MDS 9509 clock module
12
M3 x 6-mm Phillips pan-head screws
1
Disposable ESD wrist strap
Cisco MDS 9509
1
2
120141