S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
2-52
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 2 Installing the Cisco MDS 9500 Series
Removing and Installing a Power Supply or PEM
Removing and Installing the Power Supplies on the Cisco MDS 9513 Director
The Cisco MDS 9513 power supplies are located at the rear of the chassis. The physical position of the
chassis in a rack will determine how you handle the power supply when removing or installing.
Removing an AC Power Supply from the Cisco MDS 9513 Director
Warning
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,
keep hands and fingers out of the power supply bays and backplane areas.
Statement 166
To remove an AC power supply from the Cisco MDS 9513 Director, follow these steps:
Step 1
Turn the power switch on the power supply to the off (0) position. There is an internal lock mechanism
that prevents you from removing the power supply if it is not set to the off position.
Step 2
Disconnect the power cable(s) from the power source.
Step 3
Loosen the screw on the cable retention device and disconnect the power cable from the power supply.
Figure 2-27
Cable Retention Device on the 6000W Power Supply
Step 4
Loosen all four 6-32 panel fasteners at the corners of the power supply.
147966
Cable retention
device