S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
1-20
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1 Product Overview
Supervisor Modules
Table 1-4
LEDs for the Cisco MDS 9500 Series Supervisor-2 Modules
LED
Status
Description
Status
Green
All diagnostics pass. The module is operational
(normal initialization sequence).
Orange
One of the following occurs:
•
The module is booting or running diagnostics
(normal initialization sequence).
•
An over-temperature condition occurred (a minor
threshold was exceeded during environmental
monitoring).
Red
One of the following occurred:
•
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
•
An over-temperature condition occurred (a major
threshold was exceeded during environmental
monitoring).
System
Green
All chassis environmental monitors are reporting OK.
Orange
One of the following occurred:
•
The power supply failed or the power supply fan
failed.
•
Incompatible power supplies are installed.
•
The redundant clock failed.
Red
The temperature of the supervisor module exceeded
the major threshold.
Active
Green
The Supervisor-2 module is operational and active.
Orange
The Supervisor-2 module is in standby mode.
Power
Management
Green
Sufficient power is available for all modules.
Orange
Sufficient power is not available for all modules.
MGMT
10/100/1000
Ethernet Link
LED
Green
Link is up.
Off
No link.
MGMT 10/100
Ethernet
Activity LED
Green
Traffic is flowing through port.
Off
No link or no traffic.
CompactFlash
Green
The external CompactFlash card is being accessed.
Off
No activity.