Switch Specifications
The Cisco MDS 9500 Series supports hot-swappable fan modules that provide 85 cfm (cubic feet per
minute) of airflow per slot with 410 W of power dissipation per slot.
Table D-1
lists the environmental specifications for the Cisco MDS 9500 Series.
Table D-1
Environmental Specifications for the Cisco MDS 9500 Series
Description
Specification
Temperature, certified for operation
32 to 104°F (0 to 40°C)
Temperature, designed and tested for operation 32 to 130°F (0 to 55°C)
Temperature, ambient nonoperating and storage -40 to 158°F (-40 to 70°C)
Humidity (RH), ambient (noncondensing)
operating
10 to 90%
Humidity (RH), ambient (noncondensing)
nonoperating and storage
5 to 95%
Altitude, certified for operation
0 to 6500 ft (0 to 2000 m)
Altitude, designed and tested for operation
-200 to 10000 ft (-60 to 3000 m)
Noise levels
70 dB