33-15
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 33 Configuring SNMP
Configuring SNMP
The
snmp-server host
command specifies which hosts receive the notifications. The
snmp-server
enable trap
command globally enables the mechanism for the specified notification (for traps and
informs). To enable a host to receive an inform, you must configure an
snmp-server host informs
command for the host and globally enable informs by using the
snmp-server enable traps
command.
To remove the specified host from receiving traps, use the
no snmp-server host
host
global
configuration command. The
no snmp-server host
command with no keywords disables traps, but not
informs, to the host. To disable informs, use the
no snmp-server host informs
global configuration
command. To disable a specific trap type, use the
no snmp-server enable traps
notification-types
global
configuration command.
Step 6
snmp-server enable traps
notification-types
Enable the switch to send traps or informs and specify the type of
notifications to be sent. For a list of notification types, see
, or enter
snmp-server enable traps ?
To enable multiple types of traps, you must enter a separate
snmp-server
enable traps
command for each trap type.
Note
When you configure a trap by using the notification type
port-security
, configure the port security trap first, and then
configure the port security trap rate:
•
snmp-server enable traps port-security
•
snmp-server enable traps port-security trap-rate
rate
Step 7
snmp-server trap-source
interface-id
(Optional) Specify the source interface, which provides the IP address for
the trap message. This command also sets the source IP address for
informs.
Step 8
snmp-server queue-length
length
(Optional) Establish the message queue length for each trap host. The
range is 1 to 1000; the default is 10.
Step 9
snmp-server trap-timeout
seconds
(Optional) Define how often to resend trap messages. The range is 1 to
1000; the default is 30 seconds.
Step 10
end
Return to privileged EXEC mode.
Step 11
show running-config
Verify your entries.
Note
To display SNMPv3 information about
auth
|
noauth
|
priv
mode
configuration, you must enter the
show snmp user
EXEC
command.
Step 12
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Содержание Catalyst 3750-E Series
Страница 48: ...Contents xlviii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...
Страница 52: ...lii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 Preface ...
Страница 1414: ...Index IN 58 Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...