Chapter 28 Configuring LLDP, LLDP-MED, and Wired Location Service
Understanding LLDP, LLDP-MED, and Wired Location Service
Depending on the device capabilities, the switch obtains this client information at link up:
•
Slot and port specified in port connection
•
MAC address specified in the client MAC address
•
IP address specified in port connection
•
802.1X user name if applicable
•
Device category is specified as a
wired station
•
State is specified as
new
•
Serial number, UDI
•
Model number
•
Time in seconds since the switch detected the association
Depending on the device capabilities, the switch obtains this client information at link down:
•
Slot and port that was disconnected
•
MAC address
•
IP address
•
802.1X user name if applicable
•
Device category is specified as a
wired station
•
State is specified as
delete
•
Serial number, UDI
•
Time in seconds since the switch detected the disassociation
When the switch shuts down, it sends an attachment notification with the state
delete
and the IP address
before closing the NMSP connection to the MSE. The MSE interprets this notification as disassociation
for all the wired clients associated with the switch.
If you change a location address on the switch, the switch sends an NMSP location notification message
that identifies the affected ports and the changed address information.