12-33
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 12 Configuring Interface Characteristics
Configuring Layer 3 Interfaces
All Layer 3 interfaces require an IP address to route traffic. This procedure shows how to configure an
interface as a Layer 3 interface and how to assign an IP address to an interface.
Note
If the physical port is in Layer 2 mode (the default), you must enter the
no switchport
interface
configuration command to put the interface into Layer 3 mode. Entering a
no switchport
command
disables and then re-enables the interface, which might generate messages on the device to which the
interface is connected. Furthermore, when you put an interface that is in Layer 2 mode into Layer 3
mode, the previous configuration information related to the affected interface might be lost, and the
interface is returned to its default configuration
Beginning in privileged EXEC mode, follow these steps to configure a Layer 3 interface:
To remove an IP address from an interface, use the
no ip address
interface configuration command.
This example shows how to configure a port as a routed port and to assign it an IP address:
Switch#
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
interface gigabitethernet1/0/2
Switch(config-if)#
no switchport
Switch(config-if)#
ip address 192.20.135.21 255.255.255.0
Switch(config-if)#
no shutdown
Configuring SVI Autostate Exclude
Configuring SVI autostate exclude on an access or trunk port in an SVI excludes that port in the
calculation of the status of the SVI line state (up or down) status even if it belongs to the same VLAN.
When the excluded port is in the up state, and all other ports in the VLAN are in the down state, the SVI
state is changed to down.
At least one port in the VLAN should be up and not excluded to keep the SVI state up. You can use this
command to exclude the monitoring port status when determining the status of the SVI.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface
{
gigabitethernet
interface-id
} | {
vlan
vlan-id
}
| {
port-channel
port-channel-number
}
Specify the interface to be configured as a Layer 3
interface, and enter interface configuration mode.
Step 3
no switchport
For physical ports only, enter Layer 3 mode.
Step 4
ip address
ip_address subnet_mask
Configure the IP address and IP subnet.
Step 5
no shutdown
Enable the interface.
Step 6
end
Return to privileged EXEC mode.
Step 7
show interfaces
[
interface-id
]
show ip interface
[
interface-id
]
show running-config interface
[
interface-id
]
Verify the configuration.
Step 8
copy running-config startup-config
(Optional) Save your entries in the configuration file.