30-12
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 30 Configuring SPAN and RSPAN
Configuring SPAN and RSPAN
If a VLAN-based FSPAN session configured on a stack cannot fit in the hardware memory on one or
more switches, it is treated as unloaded on those switches, and traffic meant for the FSPAN ACL and
sourcing on that switch is not copied to the SPAN destination ports. The FSPAN ACL continues to be
correctly applied, and traffic is copied to the SPAN destination ports on the switches where the FSPAN
ACL fits in the hardware memory.
When an empty FSPAN ACL is attached, some hardware functions copy all traffic to the SPAN
destination ports for that ACL. If sufficient hardware resources are not available, even an empty FSPAN
ACL can be unloaded.
IPv4 and MAC FSPAN ACLs are supported on all feature sets. IPv6 FSPAN ACLs are supported only
in the advanced IP services feature set.
For information on configuring the switch for FSPAN and FRSPAN, see the
Configuring SPAN and RSPAN
•
Default SPAN and RSPAN Configuration, page 30-12
•
Configuring Local SPAN, page 30-12
•
Default SPAN and RSPAN Configuration
Configuring Local SPAN
•
SPAN Configuration Guidelines, page 30-13
•
Creating a Local SPAN Session, page 30-14
•
Creating a Local SPAN Session and Configuring Incoming Traffic, page 30-16
•
Specifying VLANs to Filter, page 30-18
Table 30-1
Default SPAN and RSPAN Configuration
Feature
Default Setting
SPAN state (SPAN and RSPAN)
Disabled.
Source port traffic to monitor
Both received and sent traffic (
both
).
Encapsulation type (destination port)
Native form (untagged packets).
Ingress forwarding (destination port)
Disabled
VLAN filtering
On a trunk interface used as a source port, all VLANs are
monitored.
RSPAN VLANs
None configured.