Configuring Online Diagnostics
Scheduling Online Diagnostics
You can schedule online diagnostics to run at a designated time of day or on a daily, weekly, or monthly
basis for a switch. Use the
no
form of this command to remove the scheduling.
Use this global configuration command to schedule online diagnostics:
Use the
no diagnostic schedule switch
number
test
{
name
|
test-id
|
test-id-range
|
all
|
basic
|
non-disruptive
} {
daily
hh
:
mm
|
on
mm
dd
yyyy
hh
:
mm
|
weekly
day-of-week
hh
:
mm
} global
configuration command to remove the scheduled tests.
This example shows how to schedule diagnostic testing for a specific day and time on a Catalyst 3560-E
switch:
Switch(config)#
diagnostic schedule test TestPortAsicCam on december 3 2006 22:25
This example shows how to schedule diagnostic testing to occur weekly at a specific time on member
switch 6 when this command is entered on a Catalyst 3750-E stack master:
Switch(config)#
diagnostic schedule switch 6 test 1-4,7 weekly saturday 10:30
For more examples, see the “Examples” section of the
diagnostic schedule
command in the command
reference for this release.
Command
Purpose
diagnostic schedule
switch
number
test
{
name
|
test-id
|
test-id-range
|
all
|
basic
|
non-disruptive
} {
daily
hh
:
mm
|
on
mm
dd
yyyy
hh
:
mm
|
weekly
day-of-week
hh
:
mm
}
Schedule on-demand diagnostic tests for a specific day and time.
The
switch
number
keyword is supported only on Catalyst 3750-E switches. The range
is from 1 to 9.
When specifying the tests to be scheduled, use these options:
•
name
—Name of the test that appears in the
show diagnostic content
command
output.
•
test-id
—ID number of the test that appears in the
show diagnostic content
command
output.
•
test-id-range
—ID numbers of the tests that appear in the
show diagnostic content
command output.
•
all
—All of the diagnostic tests.
•
basic
—Basic on-demand diagnostic tests.
•
non-disruptive
—Nondisruptive health-monitoring tests.
You can schedule the tests as follows:
•
Daily—Use the
daily
hh
:
mm
parameter.
•
Specific day and time—Use the
on
mm
dd
yyyy
hh
:
mm
parameter.
•
Weekly—Use the
weekly
day-of-week
hh
:
mm
parameter.
For detailed information about this command, see the command reference for this release.
Содержание Catalyst 3750-E Series
Страница 48: ...Contents xlviii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...
Страница 52: ...lii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 Preface ...
Страница 1414: ...Index IN 58 Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...