40-67
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 40 Configuring IP Unicast Routing
Configuring ISO CLNS Routing
These sections briefly describes how to configure IS-IS routing.
•
Default IS-IS Configuration, page 40-67
•
Enabling IS-IS Routing, page 40-68
•
Configuring IS-IS Global Parameters, page 40-70
•
Configuring IS-IS Interface Parameters, page 40-72
Default IS-IS Configuration
Table 40-12
Default IS-IS Configuration
Feature
Default Setting
Ignore link-state PDU (LSP) errors
Enabled.
IS-IS type
Conventional IS-IS: the router acts as both a Level 1 (station) and a Level 2
(area) router.
Multiarea IS-IS: the first instance of the IS-IS routing process is a Level 1-2
router. Remaining instances are Level 1 routers.
Default-information originate
Disabled.
Log IS-IS adjacency state changes.
Disabled.
LSP generation throttling timers
Maximum interval between two consecutive occurrences: 5 seconds.
Initial LSP generation delay: 50 ms.
Hold time between the first and second LSP generation: 5000 ms.
LSP maximum lifetime (without a refresh)
1200 seconds (20 minutes) before t.he LSP packet is deleted.
LSP refresh interval
Send LSP refreshes every 900 seconds (15 minutes).
Maximum LSP packet size
1497 bytes.
NSF Awareness
1
1.
NSF = Nonstop Forwarding
Enabled
2
. Allows Layer 3 switches to continue forwarding packets from a
neighboring NSF-capable router during hardware or software changes.
2.
IS-IS NSF awareness is enabled for IPv4 on switches running Cisco IOS Release 12.2(25)SEG or later.
Partial route computation (PRC) throttling
timers
Maximum PRC wait interval: 5 seconds.
Initial PRC calculation delay after a topology change: 2000 ms.
Hold time between the first and second PRC calculation: 5000 ms.
Partition avoidance
Disabled.
Password
No area or domain password is defined, and authentication is disabled.
Set-overload-bit
Disabled. When enabled, if no arguments are entered, the overload bit is set
immediately and remains set until you enter the
no set-overload-bit
command.
Shortest path first (SPF) throttling timers
Maximum interval between consecutive SFPs: 10 seconds.
Initial SFP calculation after a topology change: 5500 ms.
Holdtime between the first and second SFP calculation: 5500 ms.
Summary-address
Disabled.
Содержание Catalyst 3750-E Series
Страница 48: ...Contents xlviii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...
Страница 52: ...lii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 Preface ...
Страница 1414: ...Index IN 58 Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...