24-9
Catalyst 6500 Series Switch and Cisco 7600 Series Router Firewall Services Module Configuration Guide using ASDM
OL-20748-01
Chapter 24 Managing Software, Licenses, and Configurations
Upgrading Failover Pairs
Where
-v
is for verbose, and if
-pw
is not specified, you will be prompted for a password.
For example, to copy ASDM from a TFTP server, enter:
hostname#
copy tftp://209.165.200.226/cisco/asdm.bin flash:asdm
To copy to the ASDM from an HTTPS server, enter:
hostname#
copy http://admin:[email protected]/adsm/asdm.bin flash:asdm
Upgrading Failover Pairs
The two units in a failover configuration should have the same major (first number), minor (second
number), and maintenance (third number) software version.
However, you can have different
maintenance
versions of the software running on each unit and still
maintain failover support. You can upgrade from any maintenance release to any other maintenance
release within a minor release. For example, you can upgrade from 3.1(1) to 3.1(3) without first
installing the maintenance releases in between.
To ensure long-term compatibility and stability, we recommend upgrading both units to the same version
as soon as possible.
The FWSM does not support upgrading from between major or minor releases, for example, from 2.3 to
3.1, without downtime.
Note
To upgrade failover pairs from the maintenance partition, see the
“Installing Application Software from
the Maintenance Partition” section on page 24-5
.
This section includes the following topics:
•
Upgrading Failover Pairs to a New Maintenance Release, page 24-9
•
Upgrading Failover Pairs to a New Minor or Major Release, page 24-11
Upgrading Failover Pairs to a New Maintenance Release
You can upgrade from any maintenance release to any other maintenance release within a minor release
without downtime.
For example, you can upgrade from 3.1(1) to 3.1(3) without first installing the maintenance releases in
between.
This section includes the following topics:
•
Upgrading an Active/Standby Failover Pair to a New Maintenance Release, page 24-10
•
Upgrading an Active/Active Failover Pair to a New Maintenance Release, page 24-10
Содержание 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion
Страница 35: ...P A R T 1 Getting Started and General Information ...
Страница 36: ......
Страница 297: ...P A R T 2 Configuring the Security Policy ...
Страница 298: ......
Страница 521: ...P A R T 3 System Administration ...
Страница 522: ......
Страница 613: ...P A R T 4 Reference ...
Страница 614: ......